IVillemonteWeir Properties

Properties

dDischargedDownStreamWaterLevel Calculated Discharge derivative with UpStreamWaterLevel. Upstream is relative to the direction of chainage. Unit: [m^2/s]
(Inherited from IStructure)
dDischargedUpStreamWaterLevel Calculated Discharge derivative with DownStreamWaterLevel. Downstream is relative to the direction of chainage. Unit: [m^2/s]
(Inherited from IStructure)
Delhs Level from where the variation is forced to be linear.
(Inherited from ILinearZeroVariation)
Discharge Calculated Discharge Unit: [m^3/s]
(Inherited from IStructure)
DownstreamWaterLevel Downstream water level.Downstream refers to the direction of chainge. The water level is set by use of SetWaterLevels Unit: [m]
(Inherited from IStructure)
FlowFactor The discharge (and discharge derivatives) are scaled by the flow factor.
(Inherited from IStructure)
Height Height above invert level. Type: River Structure Geometry Unit: [m]
ID Name of the structure.
(Inherited from IStructure)
IDInUserUnit Used to get a consistent description of the structure. The ID comes in user units. Used e.g. when reporting errors, warnings and hints.
(Inherited from IStructure)
Obsolete
Implicit Flag to control if the structure is implicit or explicit. If the structure is explicit (Implicit == false) then the derivatives of the discharge are always zero. Default value: true
(Inherited from IStructure)
InvertLevel Bottom datum level. Type: River Structure Geometry Unit: [m]
InvertLevelDownstream Invert level down stream The invert level is the level where water starts flowing in to the structure from the downstream side. It does not necessarily flow through the structure.
(Inherited from IStructure)
InvertLevelUpstream Invert level up stream. The invert level is the level where water starts flowing in to the structure from the upstream side. It does not necessarily flow through the structure.
(Inherited from IStructure)
Length Length of the structure. Unit: [m]
(Inherited from IStructure)
Obsolete
Location Location of structure.
(Inherited from IStructure)
RunTimeDiagnostics The getter is used to get a list of errors. OBSOLETE
(Inherited from IStructure)
SideStructureBank Bank side that side-structure is located on

If side structure contains reservoir, and has the Coordinate set, this is not used (and should be set to Undefined).


(Inherited from IStructure)
SideStructureReservoir Reservoir at end of side structure. Null if not side structure, or no reservoir is defined
(Inherited from IStructure)
StructureType Type of structure
(Inherited from IStructure)
TopoID TopoID used when structure is searching for neighboring cross sections in the reach.
(Inherited from IStructure)
Type Structure type, unique for each type of structure.
(Inherited from IStructure)
UpstreamWaterLevel Upstream water level. Upstream refers to the direction of chainage. The water level is set by use of SetWaterLevels Unit: [m]
(Inherited from IStructure)
Valve Type of valve giving the direction of flow that is possible.
(Inherited from IValvedStructure)
WeirCoefficient Multiplication factor in the weir formula. Type: Chezy number Unit: [m^(1/2)/s]
WeirExponent Exponential coefficinet in te weir formula. Type: Dimensional factor Unit: []
Width Width of the weir opening. Width is perpendicular to the flow direction, i.e. "across the river" Type: River Structure Geometry Unit: [m]

See Also