Click or drag to resize

BieryDelleurBridge Fields

The BieryDelleurBridge type exposes the following members.

Fields
  NameDescription
Protected field_accepts
List of quantities that are accepted
(Inherited from Structure.)
Protected field_columnHeader (Inherited from BridgeTabulated.)
Protected field_controlStategyId
If the structure is being controlled, then _controlStategyId contains the ID of the active control strategy
(Inherited from Structure.)
Protected field_downstreamWaterLevel
Downstream water level, as set by SetWaterLevels(Double, Double) Unit: [m]
(Inherited from Structure.)
Protected field_dqdhDownstream
The derivative of flow through the structure with downstream water level. The flow is calculated in the derived classes when the SetWaterLevels method is called. Unit: [m2/sec]
(Inherited from Structure.)
Protected field_dqdhUpstream
The derivative of flow through the structure with upstream water level. The flow is calculated in the derived classes when the SetWaterLevels method is called. Unit: [m2/sec]
(Inherited from Structure.)
Protected field_flowArea
Flow area through structure. Used by most (but not all) structures.
(Inherited from Structure.)
Protected field_flowDir
FlowDir is used to determine which parameters to use for the flow calculations. Derived by the SetWaterLevels(Double, Double).
(Inherited from Structure.)
Public field_gridSizeDownStream (Inherited from BridgeBase.)
Public field_gridSizeUpStream (Inherited from BridgeBase.)
Protected field_id
Identification name of the structure
(Inherited from Structure.)
Protected field_implicit
If _implicit == false, then the derivatives are always zero. Default value: true.
(Inherited from Structure.)
Protected field_location
Location in the network
(Inherited from Structure.)
Protected field_offers
List of quantities that are offered
(Inherited from Structure.)
Protected field_q
Flow through the structure. The flow is calculated in the derived classes when the SetWaterLevels method is called. Unit: [m3/sec]
(Inherited from Structure.)
Protected field_rowHeader (Inherited from BridgeTabulated.)
Protected field_runTimeDiagnostics
Diagnostics are written into this Diagnostics during calculations. Set during Initialize(IDiagnostics)
(Inherited from Structure.)
Protected field_table (Inherited from BridgeTabulated.)
Protected field_topoID
Identification used to find referenced cross sections
(Inherited from Structure.)
Protected field_upstreamWaterLevel
Upstream water level, as set by SetWaterLevels(Double, Double) Unit: [m]
(Inherited from Structure.)
Protected field_waterLevelDatum (Inherited from BridgeTabulated.)
Top
See Also