NaglerBridge Properties |
The NaglerBridge type exposes the following members.
Name | Description | |
---|---|---|
Alpha | (Inherited from BridgeBase.) | |
BackRat |
Back water ratio table
(Inherited from BridgeBase.) | |
BaseCoef | (Inherited from BridgeBase.) | |
Beta | (Inherited from BridgeBase.) | |
Bottomlevel | (Inherited from BridgeBase.) | |
BridgeGeometry |
BridgeGeometry
(Inherited from BridgeBase.) | |
BridgeOverflow |
Overflow
(Inherited from BridgeBase.) | |
BridgeSubmergence |
Submergence
(Inherited from BridgeBase.) | |
BridgeTableFilePath |
Holds the filename and path of the bridge table file
(Inherited from BridgeTabulated.) | |
ColumnHeader |
Holds the header for the columns, the upstream water levels.
Type : Water level
Unit: [meter]
Default: 0.0
(Inherited from BridgeTabulated.) | |
ConvTubeNumber |
Number of tubes for conveyance tube analyses.
(Inherited from BridgeBase.) | |
CulvertID | (Inherited from BridgeBase.) | |
dDischargedDownStreamWaterLevel |
Calculated Discharge derivative with DownStreamWaterLevel. Downstream is relative to the direction of chainage.
The value is calculated by SetWaterLevels.
Unit: [m^2/s]
(Inherited from Structure.) | |
dDischargedUpStreamWaterLevel |
Calculated Discharge derivative with UpStreamWaterLevel. Upstream is relative to the direction of chainage.
The value is calculated by SetWaterLevels.
Unit: [m^2/s]
(Inherited from Structure.) | |
Delhs |
Linear flow variation.
For water level differences less than delhs use a linear Q variation
between h1-h2=delhs and h1-h2=0. This is to avoid stability problems
for small water level differences where dQdh goes to infinity.
Unit: [m]
Default: 0.01
(Inherited from BridgeTabulated.) | |
Discharge |
Calculated Discharge. The value is calculated by SetWaterLevels.
Unit: [m^3/s]
(Inherited from Structure.) | |
DisCoefType | (Inherited from BridgeBase.) | |
DownstreamWaterLevel |
Downstream water level.Downstream refers to the direction of chainage. The water level is set by use of
SetWaterLevels
Unit: [m]
(Inherited from Structure.) | |
Dykes1 | (Inherited from BridgeBase.) | |
Dykes2 | (Inherited from BridgeBase.) | |
Eccentricity | (Inherited from BridgeBase.) | |
EnchroachmentRegenerate |
Boolean telling if Enchroachment regenerate
(Inherited from BridgeBase.) | |
Entrance | (Inherited from BridgeBase.) | |
ExtensionData |
Property used by (de)serializer, when it can not find proper target for
a data field. Support of forward compatible data contracts.
(Inherited from Structure.) | |
FlowArea |
Flow area through structure. Used by most (but not all) structures.
(Inherited from Structure.) | |
FlowFactor |
The discharge (and discharge derivatives) are scaled by the flow factor.
(Inherited from Structure.) | |
Froude | (Inherited from BridgeBase.) | |
GridSizeDownStream |
Slotsize of table downstream
(Inherited from BridgeBase.) | |
GridSizeUpStream |
Slotsize of table upstream
(Inherited from BridgeBase.) | |
ID |
Structure ID
(Inherited from Structure.) | |
IDInUserUnit |
Used to get a consistent description of the structure. The ID comes in user units. Used e.g. when
reporting errors, warnings and hints.
(Inherited from Structure.) | |
Implicit |
Flag to control if the structure is implicit or explicit. If the structure is explicit
(Implicit == false) then the derivatives of the dicharge are always zero.
Default value: true
(Inherited from Structure.) | |
invert | (Inherited from BridgeBase.) | |
InvertLevelDownstream | (Inherited from BridgeBase.) | |
InvertLevelUpstream | (Inherited from BridgeBase.) | |
IsAsymmetric |
Boolean telling whether to use IsAsymmetric
(Inherited from BridgeBase.) | |
IsMultiWayOpen |
Boolean telling whether to use IsMultiWayOpen
(Inherited from BridgeBase.) | |
Length |
Length of the structure.
Unit: [m]
Default value: 0m
(Inherited from Structure.) | |
Location |
Location property.
(Inherited from Structure.) | |
MaximumWaterDepthAboveXSFactor | (Inherited from BridgeBase.) | |
Method |
Enum BridgeType defining the Bridge method used
(Inherited from BridgeBase.) | |
NumberOfCols |
Number of columns in the table
(Inherited from BridgeTabulated.) | |
NumberOfRows |
Number of rows in the table
(Inherited from BridgeTabulated.) | |
Piers | (Inherited from BridgeBase.) | |
Road1 | (Inherited from BridgeBase.) | |
Road2 | (Inherited from BridgeBase.) | |
RowHeader |
Holds the header for the rows, the downstream water levels.
Type : Water level
Unit: [meter]
Default: 0.0
(Inherited from BridgeTabulated.) | |
RunTimeDiagnostics |
The getter is used to get a list of errors.
(Inherited from Structure.) | |
SideStructureBank |
Bank side that side-structure is located on
(Inherited from Structure.)If side structure contains reservoir, and has the Coordinate set, this is not used (and should be set to Undefined). | |
SideStructureReservoir |
Reservoir at end of side structure. Null if not side structure, or no reservoir is defined
(Inherited from Structure.) | |
Skew | (Inherited from BridgeBase.) | |
SmoothBridgeSurface | (Inherited from BridgeBase.) | |
SmoothBridgeSurfaceIterations | (Inherited from BridgeBase.) | |
StructureType |
Type of structure
(Inherited from Structure.) | |
SubFac | (Inherited from BridgeBase.) | |
Submerged | (Inherited from BridgeBase.) | |
Table |
Holds the discharge table
Type : Discharge
Unit: [m3/s]
(Inherited from BridgeTabulated.) | |
TableIteration |
Variable defining maximum number of iterations for precalculating tables.
(Inherited from BridgeBase.) | |
TablesGenerated |
Boolean telling if the tables are generated
(Inherited from BridgeBase.) | |
TableSmooth |
Holds the smoothed table
Type : Water level or discharge depending on the chosen calculation mode
Unit: [m3/s] or [meter]
Default: 0.0
(Inherited from BridgeBase.) | |
TableType |
Table input filetype
0 - DFS2
1 - ASCII
Default: 0
(Inherited from BridgeTabulated.) | |
Theta | (Inherited from BridgeBase.) | |
Toplevel | (Inherited from BridgeBase.) | |
TopoID |
String used to identified cross sections
(Inherited from Structure.) | |
Type |
Structure type, unique for each type structure.
(Overrides BridgeTabulatedType.) | |
UpstreamWaterLevel |
Upstream water level. Upstream refers to the direction of chainage. The water level is set by use of
SetWaterLevels
Unit: [m]
(Inherited from Structure.) | |
UseAlpha |
The velocity distribution coefficient for bridge calculations is set to unity per default.
The coefficient may be calculated based on conveyance distribution.
Default value: false
(Inherited from BridgeBase.) | |
UseEccentricity |
Boolean telling whether to use Eccentricity
(Inherited from BridgeBase.) | |
UseFHWAReachLength |
The reach length for the FHWA method is determined based on an equal
conveyance tube analysis. if the reach length should only be based on
the physical distance from the adjacent cross section to the bridge
the variable 'USE_FHWA_REACH_LENGTH' may be used.
(Inherited from BridgeBase.) | |
UseOverflow |
Boolean telling whether to use overflow
(Inherited from BridgeBase.) | |
UsePiers |
Boolean telling whether to use Piers
(Inherited from BridgeBase.) | |
UsePiersPiles |
Boolean telling wheter to use Piers Piles
(Inherited from BridgeBase.) | |
UsePreProcessedBridgeTable |
Online or offline bridge equations.
(calculate on the fly or read from table)
Default: true
(Inherited from BridgeBase.) | |
UseSkewness |
Boolean telling whether to use Skewness
(Inherited from BridgeBase.) | |
UseSpurDykes |
Boolean telling whether to use SpurDykes
(Inherited from BridgeBase.) | |
UseSubmergence |
Boolean telling whether to use submergence
(Inherited from BridgeBase.) | |
WaterLevelDatum |
Datum to be applied to all water levels specified in the table.
Type: water level
Unit: [meter]
Default: 0.0
(Inherited from BridgeTabulated.) | |
WeirID | (Inherited from BridgeBase.) |