BridgeTabulated Class |
Namespace: DHI.Mike1D.StructureModule
The BridgeTabulated type exposes the following members.
Name | Description | |
---|---|---|
BridgeTabulated | Initializes a new instance of the BridgeTabulated class |
Name | Description | |
---|---|---|
BridgeTableFilePath |
Holds the filename and path of the bridge table file
| |
ColumnHeader |
Holds the header for the columns, the upstream water levels.
Type : Water level
Unit: [meter]
Default: 0.0
| |
dDischargedDownStreamWaterLevel |
Calculated Discharge derivative with DownStreamWaterLevel. Downstream is relative to the direction of chainage.
The value is calculated by SetWaterLevels.
Unit: [m^2/s]
(Inherited from Structure.) | |
dDischargedUpStreamWaterLevel |
Calculated Discharge derivative with UpStreamWaterLevel. Upstream is relative to the direction of chainage.
The value is calculated by SetWaterLevels.
Unit: [m^2/s]
(Inherited from Structure.) | |
Delhs |
Linear flow variation.
For water level differences less than delhs use a linear Q variation
between h1-h2=delhs and h1-h2=0. This is to avoid stability problems
for small water level differences where dQdh goes to infinity.
Unit: [m]
Default: 0.01
| |
Discharge |
Calculated Discharge. The value is calculated by SetWaterLevels.
Unit: [m^3/s]
(Inherited from Structure.) | |
DownstreamWaterLevel |
Downstream water level.Downstream refers to the direction of chainage. The water level is set by use of
SetWaterLevels
Unit: [m]
(Inherited from Structure.) | |
ExtensionData |
Property used by (de)serializer, when it can not find proper target for
a data field. Support of forward compatible data contracts.
(Inherited from Structure.) | |
FlowArea |
Flow area through structure. Used by most (but not all) structures.
(Inherited from Structure.) | |
FlowFactor |
The discharge (and discharge derivatives) are scaled by the flow factor.
(Inherited from Structure.) | |
ID |
Structure ID
(Inherited from Structure.) | |
IDInUserUnit |
Used to get a consistent description of the structure. The ID comes in user units. Used e.g. when
reporting errors, warnings and hints.
(Inherited from Structure.) | |
Implicit |
Flag to control if the structure is implicit or explicit. If the structure is explicit
(Implicit == false) then the derivatives of the dicharge are always zero.
Default value: true
(Inherited from Structure.) | |
InvertLevelDownstream | (Overrides StructureInvertLevelDownstream.) | |
InvertLevelUpstream | (Overrides StructureInvertLevelUpstream.) | |
Length |
Length of the structure.
Unit: [m]
Default value: 0m
(Inherited from Structure.) | |
Location |
Location property.
(Inherited from Structure.) | |
NumberOfCols |
Number of columns in the table
| |
NumberOfRows |
Number of rows in the table
| |
RowHeader |
Holds the header for the rows, the downstream water levels.
Type : Water level
Unit: [meter]
Default: 0.0
| |
RunTimeDiagnostics |
The getter is used to get a list of errors.
(Inherited from Structure.) | |
SideStructureBank |
Bank side that side-structure is located on
(Inherited from Structure.)If side structure contains reservoir, and has the Coordinate set, this is not used (and should be set to Undefined). | |
SideStructureReservoir |
Reservoir at end of side structure. Null if not side structure, or no reservoir is defined
(Inherited from Structure.) | |
StructureType |
Type of structure
(Inherited from Structure.) | |
Table |
Holds the discharge table
Type : Discharge
Unit: [m3/s]
| |
TableType |
Table input filetype
0 - DFS2
1 - ASCII
Default: 0
| |
TopoID |
String used to identified cross sections
(Inherited from Structure.) | |
Type |
Structure type, unique for each type structure.
(Overrides StructureType.) | |
UpstreamWaterLevel |
Upstream water level. Upstream refers to the direction of chainage. The water level is set by use of
SetWaterLevels
Unit: [m]
(Inherited from Structure.) | |
WaterLevelDatum |
Datum to be applied to all water levels specified in the table.
Type: water level
Unit: [meter]
Default: 0.0
|
Name | Description | |
---|---|---|
Accepts |
List of data types that is accepted, i.e., that you can get a ValueSetter for.
(Inherited from Structure.) | |
AllocateTable |
Allocate table of certain sizes
| |
ApplyFlowFactor |
Applies flow factor to discharge and it's derivatives
(Inherited from Structure.) | |
ControlSetFlowFactor |
Set flow factor to specified value
(Inherited from Structure.) | |
Description |
Return a string that describes this structure. Includes structure type and ID
(Inherited from Structure.) | |
Dispose |
Frees the licenses held.
(Inherited from Structure.) | |
Equals | Determines whether the specified object is equal to the current object. (Inherited from Object.) | |
ExplicitStructureSupport |
DEBUG: This method is called from Validate() if _implitcit == false to check if
the structure supports being Explicit.
Once all structures support explicit operation this method can be deleted.
(Inherited from Structure.) | |
Finalize | Allows an object to try to free resources and perform other cleanup operations before it is reclaimed by garbage collection. (Inherited from Object.) | |
GetControlAction |
Get control action for the specified id. It always returns one of
the ActionControl delegates. It will return null if
controlActionId is not valid.
(Inherited from Structure.)Base implementation for IControllable | |
GetCurrentValue |
Get the current value of the control for the specified id.
(Inherited from Structure.)Base implementation for IControllable | |
GetHashCode | Serves as the default hash function. (Inherited from Object.) | |
GetType | Gets the Type of the current instance. (Inherited from Object.) | |
Initialize(IDiagnostics) |
Set up structure and set runtime diagnostics object
(Inherited from Structure.) | |
Initialize(ICrossSection, ICrossSection, Boolean, IDiagnostics) |
Set up structure and set runtime diagnostics object
(Inherited from Structure.) | |
MemberwiseClone | Creates a shallow copy of the current Object. (Inherited from Object.) | |
Offers |
A list of quantities available from this structure
(Inherited from Structure.) | |
Prepare(HDParameterData, IDiagnostics) |
Set up structure and set runtime diagnostics object
(Inherited from Structure.) | |
Prepare(DateTime, HDParameterData, IDiagnostics) |
Set up structure and set runtime diagnostics object
(Inherited from Structure.) | |
ReadBridgeTable |
Read bridge table from file
| |
ReadBridgeTableASCII |
Read bridge table from file
| |
ReadBridgeTableDFS2 |
Read bridge table from file
| |
ResetControlledState |
Reset internal state (if any) used by controlling class.
Called after a controlling class has performed a control sequence,
and simulation is restarted.
(Inherited from Structure.)Base implementation for IControllable | |
SetControlStrategyId |
Set control strategy ID manually.
(Inherited from Structure.)Base implementation for IControllable | |
SetInputWaterLevels | (Inherited from Structure.) | |
SetWaterLevels |
Sets up- and down- stream water level and forces the calculation of the discharge and its derivatives.
(Overrides StructureSetWaterLevels(Double, Double).) | |
SetZeroFlow |
Sets the conditions for zero flow
(Inherited from Structure.) | |
ToString | Returns a string that represents the current object. (Inherited from Object.) | |
UpdatedWaterLevels |
After a time step (or iteration) has finished, update the discharge to the actual value, based
on the final water levels and the discharge derivatives.
(Inherited from Structure.) | |
Validate |
Writes errors, warnings and hints into their respective member classes. The member objects are initially cleared.
(Inherited from Structure.) | |
ValueGetter |
Get value setter for the specified data quantity
(Inherited from Structure.) | |
ValueSetter |
Get value setter for the specified data type
(Inherited from Structure.) |
Name | Description | |
---|---|---|
_accepts |
List of quantities that are accepted
(Inherited from Structure.) | |
_columnHeader | ||
_controlStategyId |
If the structure is being controlled, then _controlStategyId contains the ID of the
active control strategy
(Inherited from Structure.) | |
_downstreamWaterLevel |
Downstream water level, as set by SetWaterLevels(Double, Double)
Unit: [m]
(Inherited from Structure.) | |
_dqdhDownstream |
The derivative of flow through the structure with downstream water level. The flow is
calculated in the derived classes when the SetWaterLevels method is called.
Unit: [m2/sec]
(Inherited from Structure.) | |
_dqdhUpstream |
The derivative of flow through the structure with upstream water level. The flow is
calculated in the derived classes when the SetWaterLevels method is called.
Unit: [m2/sec]
(Inherited from Structure.) | |
_flowArea |
Flow area through structure. Used by most (but not all) structures.
(Inherited from Structure.) | |
_flowDir |
FlowDir is used to determine which parameters to use for the flow calculations.
Derived by the SetWaterLevels(Double, Double).
(Inherited from Structure.) | |
_id |
Identification name of the structure
(Inherited from Structure.) | |
_implicit |
If _implicit == false, then the derivatives are always zero.
Default value: true.
(Inherited from Structure.) | |
_location |
Location in the network
(Inherited from Structure.) | |
_offers |
List of quantities that are offered
(Inherited from Structure.) | |
_q |
Flow through the structure. The flow is calculated in the derived classes when the
SetWaterLevels method is called.
Unit: [m3/sec]
(Inherited from Structure.) | |
_rowHeader | ||
_runTimeDiagnostics |
Diagnostics are written into this Diagnostics during calculations.
Set during Initialize(IDiagnostics) (Inherited from Structure.) | |
_table | ||
_topoID |
Identification used to find referenced cross sections
(Inherited from Structure.) | |
_upstreamWaterLevel |
Upstream water level, as set by SetWaterLevels(Double, Double)
Unit: [m]
(Inherited from Structure.) | |
_waterLevelDatum |