The SewerNode type exposes the following members.
Name | Description | |
---|---|---|
BottomLevel |
Bottom level
Unit: [m]
Default: 0
(Inherited from VolumeNode.) | |
Cover |
Reference to the cover of the manhole. The cover is of type INormalCover,
ISealedCover or ISpillingCover that are all derived from ICover
| |
CriticalLevel | Obsolete.
Used in result presentation. Passed directly to the result file.
Unit: [m]
Default: 0
(Inherited from VolumeNode.) | |
GroundLevel |
Level of ground at the node.
Unit: [m]
Default: 0
(Inherited from VolumeNode.) | |
HeadLossParameterSet |
Head loss parameters for this particular node.
(Inherited from Node.) | |
Id |
Node textual identification
(Inherited from Node.) | |
MaxInflowFromSurface |
Maximum inflow from surface, i.e. rainfall runoff type inflows.
(Inherited from VolumeNode.)The node inflow from surface can be limited by the surface opening, a sewer grate or similar. Unit: [m3/s]. Default: Double.MaxValue | |
PressureReachNodeType |
Type of pressure reach node, used for pressurized sections of the network.
Default: None
(Inherited from Node.) | |
PressureReachTailCrestLevel |
Minimum water level in the outflow from pressurized sections, and hence also minimum water level in the pressurized section
(Inherited from Node.)Only applicable when PressureReachNodeType is Tail. Unit: [m] | |
XCoordinate |
X-coordinate
Unit: [m]
Default: Constants.DOUBLE_DELETE_VALUE
(Inherited from Node.) | |
YCoordinate |
Y-coordinate
Unit: [m]
Default: Constants.DOUBLE_DELETE_VALUE
(Inherited from Node.) |