IValve Interface |
Namespace: DHI.Mike1D.StructureModule
The IValve type exposes the following members.
Name | Description | |
---|---|---|
dDischargedDownStreamWaterLevel |
Calculated Discharge derivative with UpStreamWaterLevel. Upstream is relative to the direction of chainage.
Unit: [m^2/s]
(Inherited from IStructure.) | |
dDischargedUpStreamWaterLevel |
Calculated Discharge derivative with DownStreamWaterLevel. Downstream is relative to the direction of chainage.
Unit: [m^2/s]
(Inherited from IStructure.) | |
Delhs |
Level from where the variation is forced to be linear.
(Inherited from ILinearZeroVariation.) | |
Diameter |
The diameter of the valve
Type: River Structure Geometry
Unit: [m]
Default: 0
| |
Discharge |
Calculated Discharge
Unit: [m^3/s]
(Inherited from IStructure.) | |
DownstreamWaterLevel |
Downstream water level.Downstream refers to the direction of chainge. The water level is set by use of
SetWaterLevels
Unit: [m]
(Inherited from IStructure.) | |
FlowArea |
The flow area of the valve
Type: River Structure Geometry
Unit: [m2]
Default: 0
| |
FlowFactor |
The discharge (and discharge derivatives) are scaled by the flow factor.
(Inherited from IStructure.) | |
FlowFactorTable |
Table holding flow factor as a function of opening (as fractions [0;1]).
| |
ID |
Name of the structure.
(Inherited from IStructure.) | |
IDInUserUnit | Obsolete.
Used to get a consistent description of the structure. The ID comes in user units. Used e.g. when
reporting errors, warnings and hints.
(Inherited from IStructure.) | |
Implicit |
Flag to control if the structure is implicit or explicit. If the structure is explicit
(Implicit == false) then the derivatives of the discharge are always zero.
Default value: true
(Inherited from IStructure.) | |
InvertLevel |
The invert level of the valve
Type: River Structure Geometry
Unit: [m]
Default: 0
| |
InvertLevelDownstream |
Invert level down stream
The invert level is the level where water starts
flowing in to the structure from the downstream side.
It does not necessarily flow through the structure.
(Inherited from IStructure.) | |
InvertLevelUpstream |
Invert level up stream.
The invert level is the level where water starts
flowing in to the structure from the upstream side.
It does not necessarily flow through the structure.
(Inherited from IStructure.) | |
Length | Obsolete.
Length of the structure.
Unit: [m]
(Inherited from IStructure.) | |
Location |
Location of structure.
(Inherited from IStructure.) | |
MaxValveOpening |
Maximum valve opening, when valve is controlled
Unit: fraction [0;1]
| |
MaxValveSpeed |
Maximum valve speed, i.e. speed with which it can open and close
Unit: [/s] - fraction per second.
| |
MinValveOpening |
Minimum valve opening, when valve is controlled
Unit: fraction [0;1]
| |
RunTimeDiagnostics |
The getter is used to get a list of errors. OBSOLETE
(Inherited from IStructure.) | |
SideStructureBank |
Bank side that side-structure is located on
(Inherited from IStructure.)If side structure contains reservoir, and has the Coordinate set, this is not used (and should be set to Undefined). | |
SideStructureReservoir |
Reservoir at end of side structure. Null if not side structure, or no reservoir is defined
(Inherited from IStructure.) | |
StructureType |
Type of structure
(Inherited from IStructure.) | |
TopoID |
TopoID used when structure is searching for neighboring cross sections in the reach.
(Inherited from IStructure.) | |
Type |
Structure type, unique for each type of structure.
(Inherited from IStructure.) | |
UpstreamWaterLevel |
Upstream water level. Upstream refers to the direction of chainage. The water level is set by use of
SetWaterLevels
Unit: [m]
(Inherited from IStructure.) | |
Valve |
Type of valve giving the direction of flow that is possible.
(Inherited from IValvedStructure.) | |
ValveOpening |
The opening of the valve in percent. This value is overwritten if RTC is applied.
Type: River Structure Geometry
Unit: fraction [0;1]
Default: 0
|
Name | Description | |
---|---|---|
Accepts |
List of data types that is accepted, i.e., that you can get a ValueSetter for.
(Inherited from IQuantityProxy.) | |
Description |
Description of the structure.
(Inherited from IStructure.) | |
Initialize |
Set up structure and set runtime diagnostics object
(Inherited from IStructure.) | |
Offers |
List of data types that is offered, i.e., that you can get a ValueGetter for.
(Inherited from IQuantityProxy.) | |
Prepare |
Set up structure and set runtime diagnostics object
(Inherited from IStructure.) | |
SetWaterLevels |
Sets up- and down- stream water level and forces the calculation of the discharge and its derivatives.
(Inherited from IStructure.) | |
UpdatedWaterLevels |
After a time step (or iteration) has finished, update the discharge to the actual value, based
on the final water levels and the discharge derivatives.
(Inherited from IStructure.) | |
Validate |
Writes errors, warnings and hints into their respective member classes. The member objects are initially cleared.
(Inherited from IStructure.) | |
ValueGetter |
Get value setter for the specified data quantity
(Inherited from IDoubleProxy.) | |
ValueSetter |
Get value setter for the specified data type
(Inherited from IDoubleProxy.) |
Name | Description | |
---|---|---|
Getter | From the proxy, return an FuncTResult for the specified quantity. It returns the first quantity of that type that is offered, and null if the quantity is not offered. | |
Getters |
Returns a set of FuncTResult for the quantity.
We can return several quantities with the same id (usually they will differ in their description).
If the quantity is not offerent, an empty list is returned.
(Defined by ProxyExtensions.) | |
GettersFraction |
Returns a set of FuncT, TResult for the quantity.
We can return several quantities with the same id (usually they will differ in their description).
If the quantity is not offerent, an empty list is returned.
(Defined by ProxyExtensions.) | |
GetterUnboxed | From the proxy, return an FuncTResult for the specified quantity. It returns the first quantity of that type that is offered, and null if the quantity is not offered. | |
Initialize(CrossSectionData, Boolean, IDiagnostics) | Overloaded.
Helper function for some unit tests. Do not use.
(Defined by StructureExtensions.) | |
Initialize(BoundaryData, CrossSectionData, Boolean, IDiagnostics) | Overloaded.
Helper function for some unit tests. Do not use.
(Defined by StructureExtensions.) | |
IsSideStructure |
Returns true if the structure is a side structure
(Defined by StructureExtensions.) | |
Setter | From the proxy, return an IDoubleGetSet for the specified quantity. It returns the first quantity of that type that is accepted, and null if the quantity is not accepted. |