IPump Interface |
A pump moves water within the network, with the ability to start and stop at specific water levels
Namespace: DHI.Mike1D.StructureModule
The IPump type exposes the following members.
Name | Description | |
---|---|---|
AccelerationTime |
Acceleration time
| |
ConstantFlow |
Set the constant flow rate
| |
dDischargedDownStreamWaterLevel |
Calculated Discharge derivative with UpStreamWaterLevel. Upstream is relative to the direction of chainage.
Unit: [m^2/s]
(Inherited from IStructure.) | |
dDischargedUpStreamWaterLevel |
Calculated Discharge derivative with DownStreamWaterLevel. Downstream is relative to the direction of chainage.
Unit: [m^2/s]
(Inherited from IStructure.) | |
DecelerationTime |
Deceleration time
| |
Discharge |
Calculated Discharge
Unit: [m^3/s]
(Inherited from IStructure.) | |
DischargeControlActive |
Must be set to true to activate (external) control of discharge (through a PID control or similar).
If pump is controlled through ControlMoudle, this will set this automatically (during Prepare) Can not be combined with StartStopLevelControlActive | |
DownstreamWaterLevel |
Downstream water level.Downstream refers to the direction of chainge. The water level is set by use of
SetWaterLevels
Unit: [m]
(Inherited from IStructure.) | |
FlowFactor |
The discharge (and discharge derivatives) are scaled by the flow factor.
(Inherited from IStructure.) | |
HQRelation |
QH relation for QdeltaH and QH pumps,
(dH, Q) or (H, Q) pairs. The XYTable ensures that dH (or H) is always increasing.
For QdeltaH, a positive dH is the height that water must be RAISED across the pump. When DischargeControlActive is set (e.g. PID controlled pump) this HQ relation is the maximum pump capacity. Set to null if no maximum capacity. | |
HQRelationMinimumCapacity |
QH relation for QH and QdeltaH pumps
Minimum discharge allowed for a discharge controlled pump (e.g. PID).
Set to null to disable.
| |
ID |
Name of the structure.
(Inherited from IStructure.) | |
IDInUserUnit | Obsolete.
Used to get a consistent description of the structure. The ID comes in user units. Used e.g. when
reporting errors, warnings and hints.
(Inherited from IStructure.) | |
Implicit |
Flag to control if the structure is implicit or explicit. If the structure is explicit
(Implicit == false) then the derivatives of the discharge are always zero.
Default value: true
(Inherited from IStructure.) | |
InvertLevelDownstream |
Invert level down stream
The invert level is the level where water starts
flowing in to the structure from the downstream side.
It does not necessarily flow through the structure.
(Inherited from IStructure.) | |
InvertLevelUpstream |
Invert level up stream.
The invert level is the level where water starts
flowing in to the structure from the upstream side.
It does not necessarily flow through the structure.
(Inherited from IStructure.) | |
IsSideStructure | Obsolete.
A side structure is connected to a reservoir downstream (chainage direction).
| |
IsVariableSpeed |
True if the pump supports variable speed operation (must be true for PID controlled pumps).
Default value: false
| |
Length | Obsolete.
Length of the structure.
Unit: [m]
(Inherited from IStructure.) | |
Location |
Location of structure.
(Inherited from IStructure.) | |
MaxStartLevel |
Maximum stop level used if an external control is active. If an external control is active, then MinStopLevel
and MaxStopLevel must be set.
| |
MinStopLevel |
Minimum stop level used if an external control is active. If an external control is active, then MinStopLevel
and MaxStopLevel must be set.
| |
MinTimeOff |
Minimum time the pump should stay off if it stops pumping.
This is only applicable when StartStopLevelControlActive.
Default value is 0 seconds.
| |
MinTimeOn |
Minimum time the pump should stay on if it starts pumping.
This is only applicable when StartStopLevelControlActive.
Default value is 0 seconds.
| |
Offset |
Offset on water level
| |
OffsetMinDischarge |
Offset to use when looking up the minimum discharge for the pump. Only used when a PID control is
attached to the pump.
| |
OutletLevel |
Set the level of the outlet/reservoir
For side structures (StructureType == SideStructure) and flow direction is upstream (negative Q), then the downstream level is equal to this reservoir level. If Q is positive, then OutletLevel is used as the downstream end. Default value is MinValue, effectively disabling the use of the OutletLevel | |
PumpType |
Type of pump
| |
ReservoirLevel | Obsolete.
Same as OutletLevel | |
RunTimeDiagnostics |
The getter is used to get a list of errors. OBSOLETE
(Inherited from IStructure.) | |
SideStructureBank |
Bank side that side-structure is located on
(Inherited from IStructure.)If side structure contains reservoir, and has the Coordinate set, this is not used (and should be set to Undefined). | |
SideStructureReservoir |
Reservoir at end of side structure. Null if not side structure, or no reservoir is defined
(Inherited from IStructure.) | |
StartLevel |
The water level at which the pump is activated
| |
StartStopLevelControlActive |
Must be set to true to activate external control of start and stop levels (through a PID control or similar).
If pump is controlled through ControlModule, this will set this automatically (during Prepare) Can not be combined with DischargeControlActive | |
StopLevel |
The water level at which the pump is de-activated
| |
StructureType |
Type of structure
(Inherited from IStructure.) | |
TopoID |
TopoID used when structure is searching for neighboring cross sections in the reach.
(Inherited from IStructure.) | |
Type |
Structure type, unique for each type of structure.
(Inherited from IStructure.) | |
UpstreamWaterLevel |
Upstream water level. Upstream refers to the direction of chainage. The water level is set by use of
SetWaterLevels
Unit: [m]
(Inherited from IStructure.) | |
UseMaximumDischarge |
If true, then the maximum alloved discharge is taken from the MaxPumpDischargeUpstream and
MaxPumpDischargeUpstream are use to directly set the maximum discharge.
Default false.
| |
UseSuppressionFactor |
If true, then suppresion factors from the PumpSuppressionFactorUpstream and
PumpSuppressionFactorDownstream delegates are used to limit the available discharge of the pump.
Default false.
|
Name | Description | |
---|---|---|
Accepts |
List of data types that is accepted, i.e., that you can get a ValueSetter for.
(Inherited from IQuantityProxy.) | |
Description |
Description of the structure.
(Inherited from IStructure.) | |
Initialize |
Set up structure and set runtime diagnostics object
(Inherited from IStructure.) | |
Offers |
List of data types that is offered, i.e., that you can get a ValueGetter for.
(Inherited from IQuantityProxy.) | |
Prepare |
Set up structure and set runtime diagnostics object
(Inherited from IStructure.) | |
SetWaterLevels |
Sets up- and down- stream water level and forces the calculation of the discharge and its derivatives.
(Inherited from IStructure.) | |
UpdatedWaterLevels |
After a time step (or iteration) has finished, update the discharge to the actual value, based
on the final water levels and the discharge derivatives.
(Inherited from IStructure.) | |
Validate |
Writes errors, warnings and hints into their respective member classes. The member objects are initially cleared.
(Inherited from IStructure.) | |
ValueGetter |
Get value setter for the specified data quantity
(Inherited from IDoubleProxy.) | |
ValueSetter |
Get value setter for the specified data type
(Inherited from IDoubleProxy.) |
Name | Description | |
---|---|---|
Getter | From the proxy, return an FuncTResult for the specified quantity. It returns the first quantity of that type that is offered, and null if the quantity is not offered. | |
Getters |
Returns a set of FuncTResult for the quantity.
We can return several quantities with the same id (usually they will differ in their description).
If the quantity is not offerent, an empty list is returned.
(Defined by ProxyExtensions.) | |
GettersFraction |
Returns a set of FuncT, TResult for the quantity.
We can return several quantities with the same id (usually they will differ in their description).
If the quantity is not offerent, an empty list is returned.
(Defined by ProxyExtensions.) | |
GetterUnboxed | From the proxy, return an FuncTResult for the specified quantity. It returns the first quantity of that type that is offered, and null if the quantity is not offered. | |
Initialize(CrossSectionData, Boolean, IDiagnostics) | Overloaded.
Helper function for some unit tests. Do not use.
(Defined by StructureExtensions.) | |
Initialize(BoundaryData, CrossSectionData, Boolean, IDiagnostics) | Overloaded.
Helper function for some unit tests. Do not use.
(Defined by StructureExtensions.) | |
IsPumpReversed |
Check if pump is reversed, i.e. the pump is a DeltaHQTable
and the HQRelation has negative values.
(Defined by StructureExtensions.) | |
IsSideStructure |
Returns true if the structure is a side structure
(Defined by StructureExtensions.) | |
Setter | From the proxy, return an IDoubleGetSet for the specified quantity. It returns the first quantity of that type that is accepted, and null if the quantity is not accepted. |