Click or drag to resize

AbstractBroadCrestedCWeir Properties

The AbstractBroadCrestedCWeir type exposes the following members.

Properties
  NameDescription
Public propertydDischargedDownStreamWaterLevel
Calculated Discharge derivative with DownStreamWaterLevel. Downstream is relative to the direction of chainage. The value is calculated by SetWaterLevels. Unit: [m^2/s]
(Inherited from Structure.)
Public propertydDischargedUpStreamWaterLevel
Calculated Discharge derivative with UpStreamWaterLevel. Upstream is relative to the direction of chainage. The value is calculated by SetWaterLevels. Unit: [m^2/s]
(Inherited from Structure.)
Public propertyDelhs
Linear flow variation. For water level differences less than delhs use a linear Q variation between h1-h2=delhs and h1-h2=0. This is to avoid stability problems for small water level differences where dQdh goes to infinity. Unit: [m] Default: 0.01
Public propertyDischarge
Calculated Discharge. The value is calculated by SetWaterLevels. Unit: [m^3/s]
(Inherited from Structure.)
Public propertyDownstreamCrossSection
Downstream cross section data. The cros section data is the processed level, with, area. Set up during initialize, from cross section database.
Public propertyDownstreamWaterLevel
Downstream water level.Downstream refers to the direction of chainage. The water level is set by use of SetWaterLevels Unit: [m]
(Inherited from Structure.)
Public propertyExtensionData
Property used by (de)serializer, when it can not find proper target for a data field. Support of forward compatible data contracts.
(Inherited from Structure.)
Public propertyFlowArea
Flow area in the structure. Uses WaterLevelInStructure which is updated when SetWaterLevels() is called.
(Overrides StructureFlowArea.)
Public propertyFlowFactor
The discharge (and discharge derivatives) are scaled by the flow factor.
(Inherited from Structure.)
Public propertyHeadLossFreeOverflowNegativeFlow
Free overflow factor for negative flow. Default value = 1.
Public propertyHeadLossFreeOverflowPositiveFlow
Free overflow factor for positive flow. Default value = 1.
Public propertyHeadLossInflowNegativeFlow
Inflow head loss factor for positive flow. Default value = 0.5.
Public propertyHeadLossInflowPositiveFlow
Inflow head loss factor for positive flow. Default value = 0.5.
Public propertyHeadLossOutflowNegativeFlow
Free overflow factor for negative flow. Default value = 1.
Public propertyHeadLossOutflowPositiveFlow
Outflow head loss factor for positive flow. Default value = 1.
Public propertyID
Structure ID
(Inherited from Structure.)
Public propertyIDInUserUnit
Used to get a consistent description of the structure. The ID comes in user units. Used e.g. when reporting errors, warnings and hints.
(Inherited from Structure.)
Public propertyImplicit
Flag to control if the structure is implicit or explicit. If the structure is explicit (Implicit == false) then the derivatives of the dicharge are always zero. Default value: true
(Inherited from Structure.)
Public propertyInvertLevelDownstream
Invert level down stream
(Inherited from Structure.)
Public propertyInvertLevelUpstream
Invert level up stream
(Inherited from Structure.)
Public propertyIterationTolerance
Iteration tolerance. Default 0.0001
Public propertyLength
Length of the structure. Unit: [m] Default value: 0m
(Inherited from Structure.)
Public propertyLocation
Location property.
(Inherited from Structure.)
Public propertyMaximumIterations
Maximum number of iterations in a structure to obtain convergence of the discharge. Default value = 100

Currently this is set for all structures from the MaximumIterationsInStructure, but it is prepared for individual structure values.

Public propertyMinimumHeadloss
Minimum headloss across a structure. Default value = 0.1

Currently this is set for all head loss structures from the MinimumHeadloss, but it is prepared for individual structure values.

Public propertyPartOfCompositeFlow
When the culvert is part of a composite structure Q1=Q2 will differ from Qs. Qs=Q1*_partOfCompositeFlow;
Public propertyRunTimeDiagnostics
The getter is used to get a list of errors.
(Inherited from Structure.)
Public propertySideStructureBank
Bank side that side-structure is located on

If side structure contains reservoir, and has the Coordinate set, this is not used (and should be set to Undefined).

(Inherited from Structure.)
Public propertySideStructureReservoir
Reservoir at end of side structure. Null if not side structure, or no reservoir is defined
(Inherited from Structure.)
Public propertyStructureIterationCentering
Free overflow factor for negative flow. Default value = 1.
Public propertyStructureType
Type of structure
(Inherited from Structure.)
Public propertyTopoID
String used to identified cross sections
(Inherited from Structure.)
Public propertyType
Structure type, unique for each type structure.
(Inherited from Structure.)
Public propertyUpstreamCrossSection
Upstream cross section data. The cros section data is the processed level, with, area. Set up during initialize, from cross section database.
Public propertyUpstreamWaterLevel
Upstream water level. Upstream refers to the direction of chainage. The water level is set by use of SetWaterLevels Unit: [m]
(Inherited from Structure.)
Public propertyValve
Type of the valve Default: None
(Inherited from ValvedStructure.)
Public propertyWaterLevelInStructure
Water level in the structure at the latest call to SetWaterLevels()
Top
See Also