Valve Class |
Namespace: DHI.Mike1D.StructureModule
The Valve type exposes the following members.
Name | Description | |
---|---|---|
CurrentValveOpening |
For structure with control, the valve opening may change. Use this property to
get/set the current valve opening.
Unit: fraction [0;1]
| |
dDischargedDownStreamWaterLevel |
Calculated Discharge derivative with DownStreamWaterLevel. Downstream is relative to the direction of chainage.
The value is calculated by SetWaterLevels.
Unit: [m^2/s]
(Inherited from Structure.) | |
dDischargedUpStreamWaterLevel |
Calculated Discharge derivative with UpStreamWaterLevel. Upstream is relative to the direction of chainage.
The value is calculated by SetWaterLevels.
Unit: [m^2/s]
(Inherited from Structure.) | |
Delhs |
Linear flow variation.
For water level differences less than delhs use a linear Q variation
between h1-h2=delhs and h1-h2=0. This is to avoid stability problems
for small water level differences where dQdh goes to infinity.
Unit: [m]
Default: 0.01
| |
Diameter |
The diameter of the valve
Type: River Structure Geometry
Unit: [m]
Default: 0
| |
Discharge |
Calculated Discharge. The value is calculated by SetWaterLevels.
Unit: [m^3/s]
(Inherited from Structure.) | |
DownstreamWaterLevel |
Downstream water level.Downstream refers to the direction of chainage. The water level is set by use of
SetWaterLevels
Unit: [m]
(Inherited from Structure.) | |
ExtensionData |
Property used by (de)serializer, when it can not find proper target for
a data field. Support of forward compatible data contracts.
(Inherited from Structure.) | |
FlowArea |
The flow area of the valve if the gate is fully open
Type: River Structure Geometry
Unit: [m2]
Default: 0
| |
FlowFactor |
The discharge (and discharge derivatives) are scaled by the flow factor.
(Inherited from Structure.) | |
FlowFactorTable |
Table holding flow factor as a function of opening (as fraction [0;1]).
| |
ID |
Structure ID
(Inherited from Structure.) | |
IDInUserUnit |
Used to get a consistent description of the structure. The ID comes in user units. Used e.g. when
reporting errors, warnings and hints.
(Inherited from Structure.) | |
Implicit |
Flag to control if the structure is implicit or explicit. If the structure is explicit
(Implicit == false) then the derivatives of the dicharge are always zero.
Default value: true
(Inherited from Structure.) | |
InvertLevel |
The invert level of the valve
Type: River Structure Geometry
Unit: [m]
Default: 0
| |
InvertLevelDownstream |
Invert level down stream
(Overrides StructureInvertLevelDownstream.) | |
InvertLevelUpstream |
Invert level up stream
(Overrides StructureInvertLevelUpstream.) | |
Length |
Length of the structure.
Unit: [m]
Default value: 0m
(Inherited from Structure.) | |
Location |
Location property.
(Inherited from Structure.) | |
MaxValveOpening |
Maximum valve opening, when valve is controlled
Unit: fraction [0;1]
| |
MaxValveSpeed |
Maximum valve speed, i.e. speed with which it can open and close
Unit: [/s] - fraction per second
| |
MinValveOpening |
Minimum valve opening, when valve is controlled
Unit: fraction [0;1]
| |
RunTimeDiagnostics |
The getter is used to get a list of errors.
(Inherited from Structure.) | |
SideStructureBank |
Bank side that side-structure is located on
(Inherited from Structure.)If side structure contains reservoir, and has the Coordinate set, this is not used (and should be set to Undefined). | |
SideStructureReservoir |
Reservoir at end of side structure. Null if not side structure, or no reservoir is defined
(Inherited from Structure.) | |
StructureType |
Type of structure
(Inherited from Structure.) | |
TopoID |
String used to identified cross sections
(Inherited from Structure.) | |
Type |
Structure type, unique for each structure.
(Overrides StructureType.) | |
UpstreamWaterLevel |
Upstream water level. Upstream refers to the direction of chainage. The water level is set by use of
SetWaterLevels
Unit: [m]
(Inherited from Structure.) | |
Valve |
Type of the valve
Default: None
(Inherited from ValvedStructure.) | |
ValveOpening |
The opening of the valve as a fraction. This is the initial value only, the actual value may be changed if RTC is applied.
Type: River Structure Geometry
Unit: fraction [0;1]
Default: 0
|
Name | Description | |
---|---|---|
Accepts |
List of data types that is accepted, i.e., that you can get a ValueSetter for.
(Inherited from Structure.) | |
ApplyFlowFactor |
Applies flow factor to discharge and it's derivatives
(Inherited from Structure.) | |
ControlSetFlowFactor |
Set flow factor to specified value
(Inherited from Structure.) | |
ControlSetValveOpening |
Set new valve opening
| |
Description |
Return a string that describes this structure. Includes structure type and ID
(Inherited from Structure.) | |
Dispose |
Frees the licenses held.
(Inherited from Structure.) | |
Equals | Determines whether the specified object is equal to the current object. (Inherited from Object.) | |
ExplicitStructureSupport |
DEBUG: This method is called from Prepare() if _implitcit == false to check if
the structure supports being Explicit.
Once all structures support explicit operation this method can be deleted.
(Overrides StructureExplicitStructureSupport.) | |
Finalize | Allows an object to try to free resources and perform other cleanup operations before it is reclaimed by garbage collection. (Inherited from Object.) | |
GetControlAction |
Get control action for the specified id. It always returns one of
the ActionControl delegates. It will return null if
controlActionId is not valid.
(Overrides StructureGetControlAction(String).)Base implementation for IControllable | |
GetCurrentValue |
Get the current value of the control for the specified id.
(Overrides StructureGetCurrentValue(String).)Base implementation for IControllable | |
GetHashCode | Serves as the default hash function. (Inherited from Object.) | |
GetType | Gets the Type of the current instance. (Inherited from Object.) | |
Initialize(IDiagnostics) |
Set up structure and set runtime diagnostics object
(Inherited from Structure.) | |
Initialize(ICrossSection, ICrossSection, Boolean, IDiagnostics) |
Set up structure and set runtime diagnostics object
(Overrides StructureInitialize(ICrossSection, ICrossSection, Boolean, IDiagnostics).) | |
MemberwiseClone | Creates a shallow copy of the current Object. (Inherited from Object.) | |
Offers |
List of data types that is offered and can be used in GetValue
(Overrides StructureOffers.) | |
Prepare(HDParameterData, IDiagnostics) |
Set up structure and set runtime diagnostics object
(Inherited from Structure.) | |
Prepare(DateTime, HDParameterData, IDiagnostics) |
Set up structure and set runtime diagnostics object
(Inherited from Structure.) | |
PrepareTimeStep |
Prepare structure for time step
| |
ReadState |
Read state and apply to module.
Returns true if state was successfully read.
| |
ResetControlledState |
Reset internal state (if any) used by controlling class.
Called after a controlling class has performed a control sequence,
and simulation is restarted.
(Overrides StructureResetControlledState.)Base implementation for IControllable | |
SetControlStrategyId |
Set control strategy ID manually.
(Inherited from Structure.)Base implementation for IControllable | |
SetInputWaterLevels | (Inherited from Structure.) | |
SetWaterLevels |
Sets up- and down- stream water level and forces the calculation of the discharge and its derivatives.
(Overrides StructureSetWaterLevels(Double, Double).) | |
SetZeroFlow |
Sets the conditions for zero flow
(Inherited from Structure.) | |
ToString | Returns a string that represents the current object. (Inherited from Object.) | |
UpdatedWaterLevels |
After a time step (or iteration) has finished, update the discharge to the actual value, based
on the final water levels and the discharge derivatives.
(Inherited from Structure.) | |
Validate |
Validation of data for a valve structure.
(Overrides StructureValidate.) | |
ValueGetter |
Get value setter for the specified data quantity
(Overrides StructureValueGetter(Int32).) | |
ValueSetter |
Get value setter for the specified data type
(Inherited from Structure.) | |
ValveDecidesFlow |
Decides whether the valve will decide the flow and sets the flow to zero in case the valve
forbids flow.
(Inherited from ValvedStructure.) | |
WriteState |
Write current state of module
| |
ZeroFlowDueToValve |
Decides wheather the valve will prevent flow given the flow direction.
(Inherited from ValvedStructure.) |
Name | Description | |
---|---|---|
_accepts |
List of quantities that are accepted
(Inherited from Structure.) | |
_controlStategyId |
If the structure is being controlled, then _controlStategyId contains the ID of the
active control strategy
(Inherited from Structure.) | |
_downstreamWaterLevel |
Downstream water level, as set by SetWaterLevels(Double, Double)
Unit: [m]
(Inherited from Structure.) | |
_dqdhDownstream |
The derivative of flow through the structure with downstream water level. The flow is
calculated in the derived classes when the SetWaterLevels method is called.
Unit: [m2/sec]
(Inherited from Structure.) | |
_dqdhUpstream |
The derivative of flow through the structure with upstream water level. The flow is
calculated in the derived classes when the SetWaterLevels method is called.
Unit: [m2/sec]
(Inherited from Structure.) | |
_flowArea |
Flow area through structure. Used by most (but not all) structures.
(Inherited from Structure.) | |
_flowDir |
FlowDir is used to determine which parameters to use for the flow calculations.
Derived by the SetWaterLevels(Double, Double).
(Inherited from Structure.) | |
_id |
Identification name of the structure
(Inherited from Structure.) | |
_implicit |
If _implicit == false, then the derivatives are always zero.
Default value: true.
(Inherited from Structure.) | |
_location |
Location in the network
(Inherited from Structure.) | |
_offers |
List of quantities that are offered
(Inherited from Structure.) | |
_q |
Flow through the structure. The flow is calculated in the derived classes when the
SetWaterLevels method is called.
Unit: [m3/sec]
(Inherited from Structure.) | |
_runTimeDiagnostics |
Diagnostics are written into this Diagnostics during calculations.
Set during Initialize(IDiagnostics) (Inherited from Structure.) | |
_topoID |
Identification used to find referenced cross sections
(Inherited from Structure.) | |
_upstreamWaterLevel |
Upstream water level, as set by SetWaterLevels(Double, Double)
Unit: [m]
(Inherited from Structure.) | |
_valveType |
Type of the valve
Default: None
(Inherited from ValvedStructure.) |
Name | Description | |
---|---|---|
Getter | From the proxy, return an FuncTResult for the specified quantity. It returns the first quantity of that type that is offered, and null if the quantity is not offered. | |
Getters |
Returns a set of FuncTResult for the quantity.
We can return several quantities with the same id (usually they will differ in their description).
If the quantity is not offerent, an empty list is returned.
(Defined by ProxyExtensions.) | |
GettersFraction |
Returns a set of FuncT, TResult for the quantity.
We can return several quantities with the same id (usually they will differ in their description).
If the quantity is not offerent, an empty list is returned.
(Defined by ProxyExtensions.) | |
GetterUnboxed | From the proxy, return an FuncTResult for the specified quantity. It returns the first quantity of that type that is offered, and null if the quantity is not offered. | |
Initialize(CrossSectionData, Boolean, IDiagnostics) | Overloaded.
Helper function for some unit tests. Do not use.
(Defined by StructureExtensions.) | |
Initialize(BoundaryData, CrossSectionData, Boolean, IDiagnostics) | Overloaded.
Helper function for some unit tests. Do not use.
(Defined by StructureExtensions.) | |
IsSideStructure |
Returns true if the structure is a side structure
(Defined by StructureExtensions.) | |
Setter | From the proxy, return an IDoubleGetSet for the specified quantity. It returns the first quantity of that type that is accepted, and null if the quantity is not accepted. |