IOrifice Interface |
Namespace: DHI.Mike1D.StructureModule
The IOrifice type exposes the following members.
Name | Description | |
---|---|---|
dDischargedDownStreamWaterLevel |
Calculated Discharge derivative with UpStreamWaterLevel. Upstream is relative to the direction of chainage.
Unit: [m^2/s]
(Inherited from IStructure.) | |
dDischargedUpStreamWaterLevel |
Calculated Discharge derivative with DownStreamWaterLevel. Downstream is relative to the direction of chainage.
Unit: [m^2/s]
(Inherited from IStructure.) | |
Discharge |
Calculated Discharge
Unit: [m^3/s]
(Inherited from IStructure.) | |
DischargeCoefficient |
Scale factor for total discharge through orifice
| |
DownstreamWaterLevel |
Downstream water level.Downstream refers to the direction of chainge. The water level is set by use of
SetWaterLevels
Unit: [m]
(Inherited from IStructure.) | |
DownstreamXsDisplacement |
Set downstream cross section displacement
A positive value displaces the cross section to the right when looking from the upstream direction
| |
FlowFactor |
The discharge (and discharge derivatives) are scaled by the flow factor.
(Inherited from IStructure.) | |
GateLevel |
Actual gate level.
Type: River Structure Geometry
Unit: [m]
this is not a setup parameter, but a run parameter, which will change during the run (if the gate is controlled). If the gate is not explicitly controlled, this can be used to change the gate (manual/user defined control). | |
GatePolygons |
Shape of gates as polygons. Gate polygons can move
in between MinGateLevel and MaxGateLevel.
Y coordinates of gate polygons are relative to MinGateLevel If changing gate level properties during runtime, be sure to update internal state by calling PrepareForGate | |
ID |
Name of the structure.
(Inherited from IStructure.) | |
IDInUserUnit | Obsolete.
Used to get a consistent description of the structure. The ID comes in user units. Used e.g. when
reporting errors, warnings and hints.
(Inherited from IStructure.) | |
Implicit |
Flag to control if the structure is implicit or explicit. If the structure is explicit
(Implicit == false) then the derivatives of the discharge are always zero.
Default value: true
(Inherited from IStructure.) | |
InitialGateLevel |
Gate level.
Type: River Structure Geometry
Unit: [m]
Default: 0
| |
InvertLevelDownstream |
Invert level down stream
The invert level is the level where water starts
flowing in to the structure from the downstream side.
It does not necessarily flow through the structure.
(Inherited from IStructure.) | |
InvertLevelUpstream |
Invert level up stream.
The invert level is the level where water starts
flowing in to the structure from the upstream side.
It does not necessarily flow through the structure.
(Inherited from IStructure.) | |
Length | Obsolete.
Length of the structure.
Unit: [m]
(Inherited from IStructure.) | |
Location |
Location of structure.
(Inherited from IStructure.) | |
MaxGateLevel |
Maximum allowed gate level
If changing gate level properties during runtime, be sure to update internal state by calling PrepareForGate | |
MaxGateLevelDecreaseSpeed |
Maximum speed of lowering gate/weir
| |
MaxGateLevelIncreaseSpeed |
Maximum speed of rising gate/weir
| |
MinGateLevel |
Minimum allowed gate level
If changing gate level properties during runtime, be sure to update internal state by calling PrepareForGate | |
OrificePolygons |
Shape of the opening
| |
RunTimeDiagnostics |
The getter is used to get a list of errors. OBSOLETE
(Inherited from IStructure.) | |
SideStructureBank |
Bank side that side-structure is located on
(Inherited from IStructure.)If side structure contains reservoir, and has the Coordinate set, this is not used (and should be set to Undefined). | |
SideStructureReservoir |
Reservoir at end of side structure. Null if not side structure, or no reservoir is defined
(Inherited from IStructure.) | |
StructureType |
Type of structure
(Inherited from IStructure.) | |
TopoID |
TopoID used when structure is searching for neighboring cross sections in the reach.
(Inherited from IStructure.) | |
Type |
Structure type, unique for each type of structure.
(Inherited from IStructure.) | |
UpstreamWaterLevel |
Upstream water level. Upstream refers to the direction of chainage. The water level is set by use of
SetWaterLevels
Unit: [m]
(Inherited from IStructure.) | |
UpstreamXsDisplacement |
Set upstream cross section displacement
A positive value displaces the cross section to the right when looking from the upstream direction
| |
Valve |
Type of valve giving the direction of flow that is possible.
(Inherited from IValvedStructure.) |
Name | Description | |
---|---|---|
Accepts |
List of data types that is accepted, i.e., that you can get a ValueSetter for.
(Inherited from IQuantityProxy.) | |
Description |
Description of the structure.
(Inherited from IStructure.) | |
Initialize |
Set up structure and set runtime diagnostics object
(Inherited from IStructure.) | |
Offers |
List of data types that is offered, i.e., that you can get a ValueGetter for.
(Inherited from IQuantityProxy.) | |
Prepare |
Set up structure and set runtime diagnostics object
(Inherited from IStructure.) | |
PrepareForGate |
Set orifice discharge for al positions of the gate. If a control is active (a weir or gate is present)
then this must be called after:
1) Prepare()
2) Gate polygons have been defined
3) MaxGateLevel and MinGateLevel have been set.
This is called automatically in prepare. It must be called explicitly if gate polygons or max/min gate level are changed after the prepare step | |
SetWaterLevels |
Sets up- and down- stream water level and forces the calculation of the discharge and its derivatives.
(Inherited from IStructure.) | |
UpdatedWaterLevels |
After a time step (or iteration) has finished, update the discharge to the actual value, based
on the final water levels and the discharge derivatives.
(Inherited from IStructure.) | |
Validate |
Writes errors, warnings and hints into their respective member classes. The member objects are initially cleared.
(Inherited from IStructure.) | |
ValueGetter |
Get value setter for the specified data quantity
(Inherited from IDoubleProxy.) | |
ValueSetter |
Get value setter for the specified data type
(Inherited from IDoubleProxy.) |
Name | Description | |
---|---|---|
Getter | From the proxy, return an FuncTResult for the specified quantity. It returns the first quantity of that type that is offered, and null if the quantity is not offered. | |
Getters |
Returns a set of FuncTResult for the quantity.
We can return several quantities with the same id (usually they will differ in their description).
If the quantity is not offerent, an empty list is returned.
(Defined by ProxyExtensions.) | |
GettersFraction |
Returns a set of FuncT, TResult for the quantity.
We can return several quantities with the same id (usually they will differ in their description).
If the quantity is not offerent, an empty list is returned.
(Defined by ProxyExtensions.) | |
GetterUnboxed | From the proxy, return an FuncTResult for the specified quantity. It returns the first quantity of that type that is offered, and null if the quantity is not offered. | |
Initialize(CrossSectionData, Boolean, IDiagnostics) | Overloaded.
Helper function for some unit tests. Do not use.
(Defined by StructureExtensions.) | |
Initialize(BoundaryData, CrossSectionData, Boolean, IDiagnostics) | Overloaded.
Helper function for some unit tests. Do not use.
(Defined by StructureExtensions.) | |
IsSideStructure |
Returns true if the structure is a side structure
(Defined by StructureExtensions.) | |
Setter | From the proxy, return an IDoubleGetSet for the specified quantity. It returns the first quantity of that type that is accepted, and null if the quantity is not accepted. |