Click or drag to resize

IBridgeStructure Interface

Bridge structure interface

Namespace:  DHI.Mike1D.StructureModule
Assembly:  DHI.Mike1D.StructureModule (in DHI.Mike1D.StructureModule.dll) Version: 19.0.0.0 (11.1.1.1111)
Syntax
public interface IBridgeStructure : IStructure, 
	IDoubleProxy, IQuantityProxy, ILinearZeroVariation

The IBridgeStructure type exposes the following members.

Properties
  NameDescription
Public propertyAlpha
Alpha tables
Public propertyBackRat
Back water ratio table
Public propertyBaseCoef
BaseCoefficient tables
Public propertyBeta
Beta tables
Public propertyBottomlevel
Bottom level
Public propertyBridgeGeometry
BridgeGeometry
Public propertyBridgeOverflow
Overflow
Public propertyBridgeSubmergence
Submergence
Public propertyBridgeTableFilePath
Holds the smoothed table Type : Water level or discharge depending on the chosen calculation mode Unit: [m3/s] or [meter] Default: 0.0
Public propertyColumnHeader
Holds the header for the columns Type : Water level Unit: [meter] Default: 0.0
Public propertyConvTubeNumber
Number of tubes for conveyance tube analyses.
Public propertyCulvertID
The culvert used otherwise null
Public propertydDischargedDownStreamWaterLevel
Calculated Discharge derivative with UpStreamWaterLevel. Upstream is relative to the direction of chainage. Unit: [m^2/s]
(Inherited from IStructure.)
Public propertydDischargedUpStreamWaterLevel
Calculated Discharge derivative with DownStreamWaterLevel. Downstream is relative to the direction of chainage. Unit: [m^2/s]
(Inherited from IStructure.)
Public propertyDelhs
Level from where the variation is forced to be linear.
(Inherited from ILinearZeroVariation.)
Public propertyDischarge
Calculated Discharge Unit: [m^3/s]
(Inherited from IStructure.)
Public propertyDisCoefType
Loss factor Ratio Dis Coef Type, 0 - Contraction m = (1-M), 1 - Opening m = M
Public propertyDownstreamWaterLevel
Downstream water level.Downstream refers to the direction of chainge. The water level is set by use of SetWaterLevels Unit: [m]
(Inherited from IStructure.)
Public propertyDykes1
Dykes1 tables
Public propertyDykes2
Dykes2 tables
Public propertyEccentricity
Eccentricity tables
Public propertyEnchroachmentRegenerate
Boolean telling if Enchroachment regenerate
Public propertyEntrance
Entrance tables
Public propertyFlowFactor
The discharge (and discharge derivatives) are scaled by the flow factor.
(Inherited from IStructure.)
Public propertyFroude
Froude tables
Public propertyGridSizeDownStream
Slotsize of table downstream
Public propertyGridSizeUpStream
Slotsize of table upstream
Public propertyID
Name of the structure.
(Inherited from IStructure.)
Public propertyIDInUserUnit Obsolete.
Used to get a consistent description of the structure. The ID comes in user units. Used e.g. when reporting errors, warnings and hints.
(Inherited from IStructure.)
Public propertyImplicit
Flag to control if the structure is implicit or explicit. If the structure is explicit (Implicit == false) then the derivatives of the discharge are always zero. Default value: true
(Inherited from IStructure.)
Public propertyInvertLevelDownstream
Invert level down stream The invert level is the level where water starts flowing in to the structure from the downstream side. It does not necessarily flow through the structure.
(Inherited from IStructure.)
Public propertyInvertLevelUpstream
Invert level up stream. The invert level is the level where water starts flowing in to the structure from the upstream side. It does not necessarily flow through the structure.
(Inherited from IStructure.)
Public propertyIsAsymmetric
Boolean telling whether to use IsAsymmetric
Public propertyIsMultiWayOpen
Boolean telling whether to use IsMultiWayOpen
Public propertyLength Obsolete.
Length of the structure. Unit: [m]
(Inherited from IStructure.)
Public propertyLocation
Location of structure.
(Inherited from IStructure.)
Public propertyMaximumWaterDepthAboveXSFactor
Public propertyMethod
Bridge Method - FHWA, USBPR, Energy, HR, Nagler, Yarnell
Public propertyPiers
Piers tables
Public propertyRoad1
Road1 tables
Public propertyRoad2
Road2 tables
Public propertyRowHeader
Holds the header for the rows Type : Water level Unit: [meter] Default: 0.0
Public propertyRunTimeDiagnostics
The getter is used to get a list of errors. OBSOLETE
(Inherited from IStructure.)
Public propertySideStructureBank
Bank side that side-structure is located on

If side structure contains reservoir, and has the Coordinate set, this is not used (and should be set to Undefined).

(Inherited from IStructure.)
Public propertySideStructureReservoir
Reservoir at end of side structure. Null if not side structure, or no reservoir is defined
(Inherited from IStructure.)
Public propertySkew
Skew tables
Public propertySmoothBridgeSurface
Enum describing Bridge Table smoothing filer, 0 - no filter, 1-3 different filters, -1 - Max filter
Public propertySmoothBridgeSurfaceIterations
Number of iterations the smoothing filter is applied
Public propertyStructureType
Type of structure
(Inherited from IStructure.)
Public propertySubFac
SubFac tables
Public propertySubmerged
Submerged tables
Public propertyTable
Holds the table Type : Discharge Unit: [m3/s] Default: 0.0
Public propertyTableIteration
Variable defining maximum number of iterations for precalculating tables.
Public propertyTablesGenerated
Boolean telling if the tables are generated
Public propertyTableSmooth
Holds the smoothed table Type : Water level or discharge depending on the chosen calculation mode Unit: [m3/s] or [meter] Default: 0.0
Public propertyTableType
Table input filetype 0 - DFS2 1 - ASCII Default: 0
Public propertyTheta
Theta tables
Public propertyToplevel
Top level
Public propertyTopoID
TopoID used when structure is searching for neighboring cross sections in the reach.
(Inherited from IStructure.)
Public propertyType
Structure type, unique for each type of structure.
(Inherited from IStructure.)
Public propertyUpstreamWaterLevel
Upstream water level. Upstream refers to the direction of chainage. The water level is set by use of SetWaterLevels Unit: [m]
(Inherited from IStructure.)
Public propertyUseAlpha
The velocity distribution coefficient for bridge calculations is set to unity per default. The coefficient may be calculated based on conveyance distribution. Default value: false
Public propertyUseEccentricity
Boolean telling whether to use Eccentricity
Public propertyUseFHWAReachLength
The reach length for the FHWA method is determined based on an equal conveyance tube analysis. If the reach length should only be based on the physical distance from the adjacent cross section to the bridge the variable 'USE_FHWA_REACH_LENGTH' may be used.
Public propertyUseOverflow
Boolean telling whether to use overflow
Public propertyUsePiers
Boolean telling whether to use Piers
Public propertyUsePiersPiles
Boolean telling wheter to use Piers Piles
Public propertyUsePreProcessedBridgeTable
Use preprocessed bridge tables
Public propertyUseSkewness
Boolean telling whether to use Skewness
Public propertyUseSpurDykes
Boolean telling whether to use SpurDykes
Public propertyUseSubmergence
Boolean telling whether to use submergence
Public propertyWaterLevelDatum
Datum to be applied to all water levels specified in the table. Type: water level Unit: [meter] Default: 0.0
Public propertyWeirID
The weir used otherwise null
Top
Methods
  NameDescription
Public methodAccepts
List of data types that is accepted, i.e., that you can get a ValueSetter for.
(Inherited from IQuantityProxy.)
Public methodAllocateTable
allocates Table, RowHeader and ColumnHeader with the specified sizes. Furthermore allocated _tableSmooth for smoothing the Table
Public methodCheckBridgeCombinations
Check bridge combinations
Public methodDescription
Description of the structure.
(Inherited from IStructure.)
Public methodInitialize
Set up structure and set runtime diagnostics object
(Inherited from IStructure.)
Public methodOffers
List of data types that is offered, i.e., that you can get a ValueGetter for.
(Inherited from IQuantityProxy.)
Public methodPrepare
Set up structure and set runtime diagnostics object
(Inherited from IStructure.)
Public methodSetInvertLevel
Set up invert level
Public methodSetWaterLevels
Sets up- and down- stream water level and forces the calculation of the discharge and its derivatives.
(Inherited from IStructure.)
Public methodUpdatedWaterLevels
After a time step (or iteration) has finished, update the discharge to the actual value, based on the final water levels and the discharge derivatives.
(Inherited from IStructure.)
Public methodValidate
Writes errors, warnings and hints into their respective member classes. The member objects are initially cleared.
(Inherited from IStructure.)
Public methodValueGetter
Get value setter for the specified data quantity
(Inherited from IDoubleProxy.)
Public methodValueSetter
Get value setter for the specified data type
(Inherited from IDoubleProxy.)
Top
Extension Methods
  NameDescription
Public Extension MethodGetter

From the proxy, return an FuncTResult for the specified quantity.

It returns the first quantity of that type that is offered, and null if the quantity is not offered.

(Defined by ProxyExtensions.)
Public Extension MethodGetters
Returns a set of FuncTResult for the quantity. We can return several quantities with the same id (usually they will differ in their description). If the quantity is not offerent, an empty list is returned.
(Defined by ProxyExtensions.)
Public Extension MethodGettersFraction
Returns a set of FuncT, TResult for the quantity. We can return several quantities with the same id (usually they will differ in their description). If the quantity is not offerent, an empty list is returned.
(Defined by ProxyExtensions.)
Public Extension MethodGetterUnboxed

From the proxy, return an FuncTResult for the specified quantity.

It returns the first quantity of that type that is offered, and null if the quantity is not offered.

(Defined by ProxyExtensions.)
Public Extension MethodInitialize(CrossSectionData, Boolean, IDiagnostics)Overloaded.
Helper function for some unit tests. Do not use.
(Defined by StructureExtensions.)
Public Extension MethodInitialize(BoundaryData, CrossSectionData, Boolean, IDiagnostics)Overloaded.
Helper function for some unit tests. Do not use.
(Defined by StructureExtensions.)
Public Extension MethodIsSideStructure
Returns true if the structure is a side structure
(Defined by StructureExtensions.)
Public Extension MethodSetter

From the proxy, return an IDoubleGetSet for the specified quantity.

It returns the first quantity of that type that is accepted, and null if the quantity is not accepted.

(Defined by ProxyExtensions.)
Top
See Also