Click or drag to resize

EnergyLoss Class

Calculation of the flow at energy loss structures.
Inheritance Hierarchy

Namespace:  DHI.Mike1D.StructureModule
Assembly:  DHI.Mike1D.StructureModule (in DHI.Mike1D.StructureModule.dll) Version: 19.0.0.0 (11.1.1.1111)
Syntax
public class EnergyLoss : Structure, IEnergyLoss, 
	IStructure, IDoubleProxy, IQuantityProxy, ISolvesEnergyEquation, ILinearZeroVariation, 
	IStructureCrossSectionSetup, IControllable

The EnergyLoss type exposes the following members.

Constructors
  NameDescription
Public methodEnergyLoss
Constructor method for the energy losss
Top
Properties
  NameDescription
Public propertyAbruptAlignmentChange
Angle in degress describing abrupt change in river alignment Type: angle Unit: [degress] Default: 0.0
Public propertydDischargedDownStreamWaterLevel
Calculated Discharge derivative with DownStreamWaterLevel. Downstream is relative to the direction of chainage. The value is calculated by SetWaterLevels. Unit: [m^2/s]
(Inherited from Structure.)
Public propertydDischargedUpStreamWaterLevel
Calculated Discharge derivative with UpStreamWaterLevel. Upstream is relative to the direction of chainage. The value is calculated by SetWaterLevels. Unit: [m^2/s]
(Inherited from Structure.)
Public propertyDelhs
Linear flow variation. For water level differences less than delhs use a linear Q variation between h1-h2=delhs and h1-h2=0. This is to avoid stability problems for small water level differences where dQdh goes to infinity. Unit: [m] Default: 0.01
Public propertyDischarge
Calculated Discharge. The value is calculated by SetWaterLevels. Unit: [m^3/s]
(Inherited from Structure.)
Public propertyDownstreamCrossSection
Downstream cross section data. The cross section data is the processed level, with, area.
Public propertyDownstreamWaterLevel
Downstream water level.Downstream refers to the direction of chainage. The water level is set by use of SetWaterLevels Unit: [m]
(Inherited from Structure.)
Public propertyExtensionData
Property used by (de)serializer, when it can not find proper target for a data field. Support of forward compatible data contracts.
(Inherited from Structure.)
Public propertyFlowArea
Flow area through structure. Used by most (but not all) structures.
(Inherited from Structure.)
Public propertyFlowFactor
The discharge (and discharge derivatives) are scaled by the flow factor.
(Inherited from Structure.)
Public propertyFrictionFactor
Frictionfactor used to calculate the energy loss caused by ordinary friction. Type: Dimensional factor Unit: [s2/m6] Default: 0.001
Public propertyGradualAlignmentChange
Angle in degress describing gradual change in river alignment Type: angle Unit: [degress] Default: 0.0
Public propertyHorizontalOffSetFromMarker2
Value used when plotting the structue Unit: [m] Defualt: 0
Public propertyID
Structure ID
(Inherited from Structure.)
Public propertyIDInUserUnit
Used to get a consistent description of the structure. The ID comes in user units. Used e.g. when reporting errors, warnings and hints.
(Inherited from Structure.)
Public propertyImplicit
Flag to control if the structure is implicit or explicit. If the structure is explicit (Implicit == false) then the derivatives of the dicharge are always zero. Default value: true
(Inherited from Structure.)
Public propertyInvertLevelDownstream
Invert level down stream
(Overrides StructureInvertLevelDownstream.)
Public propertyInvertLevelUpstream
Invert level up stream
(Overrides StructureInvertLevelUpstream.)
Public propertyLength
Length of the structure. Unit: [m] Default value: 0m
(Inherited from Structure.)
Public propertyLocation
Location property.
(Inherited from Structure.)
Public propertyMinimumHeadloss
Minimum head loss across a structure. Default value = 0.01
Public propertyNegContraction
Energy loss coefficient for negative flow at flow contraction losses Type: Dimensional factor Unit: [] Default: 0.0
Public propertyNegExpansion
Energy loss coefficient for negative flow at flow expansion losses Type: Dimensional factor Unit: [] Default: 0.0
Public propertyNegUserDefined
Energy loss coefficient for negative flow at user defined energy losses Type: Dimensional factor Unit: [] Default: 0.0
Public propertyPartOfCompositeFlow
Part of the flow in a parallel strucutre that passes through this structure.
Public propertyPosContraction
Energy loss coefficient for positive flow at flow contraction losses Type: Dimensional factor Unit: [] Default: 0.0
Public propertyPosExpansion
Energy loss coefficient for positive flow at flow expansion losses Type: Dimensional factor Unit: [] Default: 0.0
Public propertyPosUserDefined
Energy loss coefficient for positive flow at user defined energy losses Type: Dimensional factor Unit: [] Default: 0.0
Public propertyRoughness
Roughness for gradual change in river alignment Type: Dimensional factor Unit: [] Default: 0.0
Public propertyRunTimeDiagnostics
The getter is used to get a list of errors.
(Inherited from Structure.)
Public propertySideStructureBank
Bank side that side-structure is located on

If side structure contains reservoir, and has the Coordinate set, this is not used (and should be set to Undefined).

(Inherited from Structure.)
Public propertySideStructureReservoir
Reservoir at end of side structure. Null if not side structure, or no reservoir is defined
(Inherited from Structure.)
Public propertyStructureCrossSection
Structure cross section data. The cross section data is the processed level, with, area.
Public propertyStructureType
Type of structure
(Inherited from Structure.)
Public propertyTopoID
String used to identified cross sections
(Inherited from Structure.)
Public propertyType
Structure type, unique for each structure.
(Overrides StructureType.)
Public propertyUpstreamCrossSection
Upstream cross section data. The cross section data is the processed level, with, area.
Public propertyUpstreamWaterLevel
Upstream water level. Upstream refers to the direction of chainage. The water level is set by use of SetWaterLevels Unit: [m]
(Inherited from Structure.)
Public propertyUseAbruptChange
Flag telling if there is energy loss due to an abrupt change in river alingment Type: boolean Default: false
Public propertyUseContractionLoss
Flag telling if there is an energy loss due to a contraction Type: boolean Default: false
Public propertyUseExpansionLoss
Flag telling if there is an energy loss due to a expansion Type: boolean Default: false
Public propertyUseGradualChange
Flag telling if there is energy loss due to a gradual change in river alingment Type: boolean Default: false
Public propertyUseUserDefined
Flag telling if there is an user defined energy loss Type: boolean Default: false
Public propertyWaterLevel
Water level at the structure
Top
Methods
  NameDescription
Public methodAccepts
List of data types that is accepted, i.e., that you can get a ValueSetter for.
(Inherited from Structure.)
Protected methodApplyFlowFactor
Applies flow factor to discharge and it's derivatives
(Inherited from Structure.)
Public methodControlSetFlowFactor
Set flow factor to specified value
(Inherited from Structure.)
Public methodDescription
Return a string that describes this structure. Includes structure type and ID
(Inherited from Structure.)
Public methodDispose
Frees the licenses held.
(Inherited from Structure.)
Public methodEquals
Determines whether the specified object is equal to the current object.
(Inherited from Object.)
Protected methodExplicitStructureSupport
DEBUG: This method is called from Validate() if _implitcit == false to check if the structure supports being Explicit. Once all structures support explicit operation this method can be deleted.
(Inherited from Structure.)
Protected methodFinalize
Allows an object to try to free resources and perform other cleanup operations before it is reclaimed by garbage collection.
(Inherited from Object.)
Public methodGetControlAction
Get control action for the specified id. It always returns one of the ActionControl delegates. It will return null if controlActionId is not valid.

Base implementation for IControllable

(Inherited from Structure.)
Public methodGetCurrentValue
Get the current value of the control for the specified id.

Base implementation for IControllable

(Inherited from Structure.)
Public methodGetHashCode
Serves as the default hash function.
(Inherited from Object.)
Public methodGetType
Gets the Type of the current instance.
(Inherited from Object.)
Public methodInitialize(IDiagnostics)
Set up structure and set runtime diagnostics object
(Inherited from Structure.)
Public methodInitialize(ICrossSection, ICrossSection, Boolean, IDiagnostics)
Prepare the weir: Set the cross sections on each side of the weir.
(Overrides StructureInitialize(ICrossSection, ICrossSection, Boolean, IDiagnostics).)
Protected methodMemberwiseClone
Creates a shallow copy of the current Object.
(Inherited from Object.)
Public methodOffers
A list of quantities available from this structure
(Inherited from Structure.)
Public methodPrepare(HDParameterData, IDiagnostics)
Set up structure and set runtime diagnostics object
(Overrides StructurePrepare(HDParameterData, IDiagnostics).)
Public methodPrepare(DateTime, HDParameterData, IDiagnostics)
Set up structure and set runtime diagnostics object
(Inherited from Structure.)
Public methodResetControlledState
Reset internal state (if any) used by controlling class. Called after a controlling class has performed a control sequence, and simulation is restarted.

Base implementation for IControllable

(Inherited from Structure.)
Public methodSetControlStrategyId
Set control strategy ID manually.

Base implementation for IControllable

(Inherited from Structure.)
Protected methodSetInputWaterLevels (Inherited from Structure.)
Public methodSetup
Set cross section information to structure
Public methodSetWaterLevels(Double, Double)
Sets up- and down- stream water level and forces the calculation of the discharge and its derivatives.
(Overrides StructureSetWaterLevels(Double, Double).)
Public methodSetWaterLevels(Double, Double, Double, Double)
Sets up- and down-stream water level and forces the calculation of the discharge and its derivatives.
Protected methodSetZeroFlow
Sets the conditions for zero flow
(Inherited from Structure.)
Public methodToString
Returns a string that represents the current object.
(Inherited from Object.)
Public methodUpdatedWaterLevels
After a time step (or iteration) has finished, update the discharge to the actual value, based on the final water levels and the discharge derivatives.
(Inherited from Structure.)
Public methodValidate
Validation of data for a energy loss structure.
(Overrides StructureValidate.)
Public methodValueGetter
Get value setter for the specified data quantity
(Inherited from Structure.)
Public methodValueSetter
Get value setter for the specified data type
(Inherited from Structure.)
Top
Fields
  NameDescription
Protected field_accepts
List of quantities that are accepted
(Inherited from Structure.)
Protected field_controlStategyId
If the structure is being controlled, then _controlStategyId contains the ID of the active control strategy
(Inherited from Structure.)
Protected field_downstreamWaterLevel
Downstream water level, as set by SetWaterLevels(Double, Double) Unit: [m]
(Inherited from Structure.)
Protected field_dqdhDownstream
The derivative of flow through the structure with downstream water level. The flow is calculated in the derived classes when the SetWaterLevels method is called. Unit: [m2/sec]
(Inherited from Structure.)
Protected field_dqdhUpstream
The derivative of flow through the structure with upstream water level. The flow is calculated in the derived classes when the SetWaterLevels method is called. Unit: [m2/sec]
(Inherited from Structure.)
Protected field_flowArea
Flow area through structure. Used by most (but not all) structures.
(Inherited from Structure.)
Protected field_flowDir
FlowDir is used to determine which parameters to use for the flow calculations. Derived by the SetWaterLevels(Double, Double).
(Inherited from Structure.)
Protected field_id
Identification name of the structure
(Inherited from Structure.)
Protected field_implicit
If _implicit == false, then the derivatives are always zero. Default value: true.
(Inherited from Structure.)
Protected field_location
Location in the network
(Inherited from Structure.)
Protected field_offers
List of quantities that are offered
(Inherited from Structure.)
Protected field_partOfCompositeFlow
When the energy loss structure is part of a composite structure Q1=Q2 will differ from Qs. Qs=Q1*_partOfCompositeFlow;
Protected field_q
Flow through the structure. The flow is calculated in the derived classes when the SetWaterLevels method is called. Unit: [m3/sec]
(Inherited from Structure.)
Protected field_runTimeDiagnostics
Diagnostics are written into this Diagnostics during calculations. Set during Initialize(IDiagnostics)
(Inherited from Structure.)
Protected field_topoID
Identification used to find referenced cross sections
(Inherited from Structure.)
Protected field_upstreamWaterLevel
Upstream water level, as set by SetWaterLevels(Double, Double) Unit: [m]
(Inherited from Structure.)
Public fieldSolverMethod
Solution method for solving the energy equations
Public fieldUseQCrit
Flag for the NR solver
Top
Extension Methods
  NameDescription
Public Extension MethodGetter

From the proxy, return an FuncTResult for the specified quantity.

It returns the first quantity of that type that is offered, and null if the quantity is not offered.

(Defined by ProxyExtensions.)
Public Extension MethodGetters
Returns a set of FuncTResult for the quantity. We can return several quantities with the same id (usually they will differ in their description). If the quantity is not offerent, an empty list is returned.
(Defined by ProxyExtensions.)
Public Extension MethodGettersFraction
Returns a set of FuncT, TResult for the quantity. We can return several quantities with the same id (usually they will differ in their description). If the quantity is not offerent, an empty list is returned.
(Defined by ProxyExtensions.)
Public Extension MethodGetterUnboxed

From the proxy, return an FuncTResult for the specified quantity.

It returns the first quantity of that type that is offered, and null if the quantity is not offered.

(Defined by ProxyExtensions.)
Public Extension MethodInitialize(CrossSectionData, Boolean, IDiagnostics)Overloaded.
Helper function for some unit tests. Do not use.
(Defined by StructureExtensions.)
Public Extension MethodInitialize(BoundaryData, CrossSectionData, Boolean, IDiagnostics)Overloaded.
Helper function for some unit tests. Do not use.
(Defined by StructureExtensions.)
Public Extension MethodIsSideStructure
Returns true if the structure is a side structure
(Defined by StructureExtensions.)
Public Extension MethodSetter

From the proxy, return an IDoubleGetSet for the specified quantity.

It returns the first quantity of that type that is accepted, and null if the quantity is not accepted.

(Defined by ProxyExtensions.)
Top
See Also