Public propertyActualGateLevel
Actual gate level. Type: River Structure Geometry Unit: [m] Default: 0

this is not a setup parameter, but a run parameter, which will change during the run (if the gate is controlled). If the gate is not controlled, this can be used to change the gate (manual/user defined control).

(Inherited from Gate.)
Public propertyCfA
Factor used when calculating Yc for controlled free flow Type: Dimensional factor Unit: [] Default: 0.89
Public propertyCfB
Exponent used when calculating Yc for controlled free flow Type: Dimensional factor Unit: [] Default: 0.17
Public propertyCsA
Factor used when calculating Yc for controlled submerged flow Type: Dimensional factor Unit: [] Default: 1.12
Public propertyCsB
Exponent used when calculating Yc for controlled submerged flow Type: Dimensional factor Unit: [] Default: 0.21
Public propertydDischargedDownStreamWaterLevel
Calculated Discharge derivative with DownStreamWaterLevel. Downstream is relative to the direction of chainage. The value is calculated by SetWaterLevels. Unit: [m^2/s]
(Inherited from Structure.)
Public propertydDischargedUpStreamWaterLevel
Calculated Discharge derivative with UpStreamWaterLevel. Upstream is relative to the direction of chainage. The value is calculated by SetWaterLevels. Unit: [m^2/s]
(Inherited from Structure.)
Public propertyDelhs
Linear flow variation. For water level differences less than delhs use a linear Q variation between h1-h2=delhs and h1-h2=0. This is to avoid stability problems for small water level differences where dQdh goes to infinity. Unit: [m] Default: 0.01
Public propertyDischarge
Calculated Discharge. The value is calculated by SetWaterLevels. Unit: [m^3/s]
(Inherited from Structure.)
Public propertyDownstreamWaterLevel
Downstream water level.Downstream refers to the direction of chainage. The water level is set by use of SetWaterLevels Unit: [m]
(Inherited from Structure.)
Public propertyDynamicMaxGateLevel
Controllable maximum gate level
(Inherited from Gate.)
Public propertyDynamicMinGateLevel
Controllable minimum gate level
(Inherited from Gate.)
Public propertyExtensionData
Property used by (de)serializer, when it can not find proper target for a data field. Support of forward compatible data contracts.
(Inherited from Structure.)
Public propertyFlowArea
Flow area through structure. Used by most (but not all) structures.
(Inherited from Structure.)
Public propertyFlowFactor
The discharge (and discharge derivatives) are scaled by the flow factor.
(Inherited from Structure.)
Public propertyHeight
The height of the gate. This is used to evaluate if over topping can occur. Type: River Structure Geometry Unit: [m] Default: 0
Public propertyHorizontalOffSetFromMarker2
Value used when plotting the structue Unit: [m] Defualt: 0
Public propertyID
Structure ID
(Inherited from Structure.)
Public propertyIDInUserUnit
Used to get a consistent description of the structure. The ID comes in user units. Used e.g. when reporting errors, warnings and hints.
(Inherited from Structure.)
Public propertyImplicit
Flag to control if the structure is implicit or explicit. If the structure is explicit (Implicit == false) then the derivatives of the dicharge are always zero. Default value: true
(Inherited from Structure.)
Public propertyInitialGateLevel
Initial value of the gate level. Type: River Structure Geometry Unit: [m] Default: 0
(Inherited from Gate.)
Public propertyInvertLevelDownstream
Invert level down stream
(Overrides StructureInvertLevelDownstream.)
Public propertyInvertLevelUpstream
Invert level up stream
(Overrides StructureInvertLevelUpstream.)
Public propertyLength
Length of the structure. Unit: [m] Default value: 0m
(Inherited from Structure.)
Public propertyLocation
Location property.
(Inherited from Structure.)
Public propertyLowerLimit1
Lower limit between controlled submerged flow and controlled free flow Type: Dimensional factor Unit: [] Default: 0.95
Public propertyLowerLimit2
Lower limit between controlled free flow and uncontrolled submerged flow Type: Dimensional factor Unit: [] Default: 1.45
Public propertyLowerLimit3
Lower limit between uncontrolled submerged flow and uncontrolled free flow Type: Dimensional factor Unit: [] Default: 0.6
Public propertyMaxSpeed
The maximum allowed rate of change of the gate level. Type: River Structure Geometry / Time Unit: [m] Default: 0.001
(Inherited from Gate.)
Public propertyMaxValue
Maximum gate level. The gate can not be raised above this level. Type: River Structure Geometry Unit: [m] Default: 0
(Inherited from Gate.)
Public propertyMultiplicator
Multiplicator or "number of structures" of this type. Used for modelling more structures at the same location with the same geometry in one go. Unit: [] Default: 1
(Inherited from Gate.)
Public propertyRunTimeDiagnostics
The getter is used to get a list of errors.
(Inherited from Structure.)
Public propertySideStructureBank
Bank side that side-structure is located on

If side structure contains reservoir, and has the Coordinate set, this is not used (and should be set to Undefined).

(Inherited from Structure.)
Public propertySideStructureReservoir
Reservoir at end of side structure. Null if not side structure, or no reservoir is defined
(Inherited from Structure.)
Public propertySillLevel
Level of the sill of the gate. Type: River Structure Geometry Unit: [m] Default: 0
(Inherited from Gate.)
Public propertyStructureType
Type of structure
(Inherited from Structure.)
Public propertyTopoID
String used to identified cross sections
(Inherited from Structure.)
Public propertyType
Structure type, unique for each structure.
(Overrides StructureType.)
Public propertyUfA
Factor used when calculating Yc for uncontrolled free flow and overtopping flow Type: Dimensional factor Unit: [] Default: 0.77
Public propertyUpperLimit1
Upper limit between controlled submerged flow and controlled free flow Type: Dimensional factor Unit: [] Default: 1.05
Public propertyUpperLimit2
Upper limit between controlled free flow and uncontrolled submerged flow Type: Dimensional factor Unit: [] Default: 1.55
Public propertyUpperLimit3
Upper limit between uncontrolled submerged flow and uncontrolled free flow Type: Dimensional factor Unit: [] Default: 0.7
Public propertyUpstreamWaterLevel
Upstream water level. Upstream refers to the direction of chainage. The water level is set by use of SetWaterLevels Unit: [m]
(Inherited from Structure.)
Public propertyUsA
Factor used when calculating Yc for uncontrolled submerged flow Type: Dimensional factor Unit: [] Default: 0.86
Public propertyUsB
Exponent used when calculating Yc for uncontrolled submerged flow Type: Dimensional factor Unit: [] Default: 0.38
Public propertyUseControlledMaxGateLevel
Use the controllable maximum gate level
(Inherited from Gate.)
Public propertyUseControlledMinGateLevel
Use the controllable minimum gate level
(Inherited from Gate.)
Public propertyUseMaxValue
Flag telling if the maximum gate level specified in _maxValue should be used Type: boolean Unit: [m] Default: false
(Inherited from Gate.)
Public propertyUseMomentumEquation
Flag to de-activate structure completely. If this flag is set, then the momentum equation will be used to set the coefficents in HDStructureGridPoint instead of the structure. The flag is cleared the next time Control() is called.

This is used in HDStructureGridPoint to determine if the structure should be active or or if the coefficients should be set using a HDQGridPoint.

(Inherited from Gate.)
Public propertyWidth
Width of the weir opening. Width is perpendicular to the flow direction, i.e. "across the river"
(Inherited from Gate.)