ITabulated Properties |
The ITabulated type exposes the following members.
Name | Description | |
---|---|---|
CalculationMode |
Integer telling how the table should be interpreted
When 0 then Q = f(Hups, Hdws)
When 1 then Hups = f(Hdws, Q)
When 2 then Hdws = f(Hups, Q)
Type: dimensionless
Unit: []
Default: 0
| |
ColumnHeader |
Holds the header for the columns
Type : Water level or discharge depending on the chosen calculation mode
Unit: [m3/s] or [meter]
Default: 0.0
| |
dDischargedDownStreamWaterLevel |
Calculated Discharge derivative with UpStreamWaterLevel. Upstream is relative to the direction of chainage.
Unit: [m^2/s]
(Inherited from IStructure.) | |
dDischargedUpStreamWaterLevel |
Calculated Discharge derivative with DownStreamWaterLevel. Downstream is relative to the direction of chainage.
Unit: [m^2/s]
(Inherited from IStructure.) | |
Delhs |
Level from where the variation is forced to be linear.
(Inherited from ILinearZeroVariation.) | |
Discharge |
Calculated Discharge
Unit: [m^3/s]
(Inherited from IStructure.) | |
DischargeFactor |
Factor that are multiplied with the discharge found from the table.
Type: discharge
Unit: [m3/s]
Default: 1.0
| |
DownstreamWaterLevel |
Downstream water level.Downstream refers to the direction of chainge. The water level is set by use of
SetWaterLevels
Unit: [m]
(Inherited from IStructure.) | |
FlowFactor |
The discharge (and discharge derivatives) are scaled by the flow factor.
(Inherited from IStructure.) | |
ID |
Name of the structure.
(Inherited from IStructure.) | |
IDInUserUnit | Obsolete.
Used to get a consistent description of the structure. The ID comes in user units. Used e.g. when
reporting errors, warnings and hints.
(Inherited from IStructure.) | |
Implicit |
Flag to control if the structure is implicit or explicit. If the structure is explicit
(Implicit == false) then the derivatives of the discharge are always zero.
Default value: true
(Inherited from IStructure.) | |
InvertLevelDownstream |
Invert level down stream
The invert level is the level where water starts
flowing in to the structure from the downstream side.
It does not necessarily flow through the structure.
(Inherited from IStructure.) | |
InvertLevelUpstream |
Invert level up stream.
The invert level is the level where water starts
flowing in to the structure from the upstream side.
It does not necessarily flow through the structure.
(Inherited from IStructure.) | |
Length | Obsolete.
Length of the structure.
Unit: [m]
(Inherited from IStructure.) | |
Location |
Location of structure.
(Inherited from IStructure.) | |
NumberOfCols |
Number of columns in the table
| |
NumberOfRows |
Number of rows
| |
RowHeader |
Holds the header for the rows
Type : Water level
Unit: [meter]
Default: 0.0
| |
RunTimeDiagnostics |
The getter is used to get a list of errors. OBSOLETE
(Inherited from IStructure.) | |
SideStructureBank |
Bank side that side-structure is located on
(Inherited from IStructure.)If side structure contains reservoir, and has the Coordinate set, this is not used (and should be set to Undefined). | |
SideStructureReservoir |
Reservoir at end of side structure. Null if not side structure, or no reservoir is defined
(Inherited from IStructure.) | |
StructureType |
Type of structure
(Inherited from IStructure.) | |
Table |
Holds the table
Type : Water level or discharge depending on the chosen calculation mode
Unit: [m3/s] or [meter]
Default: 0.0
| |
TopoID |
TopoID used when structure is searching for neighboring cross sections in the reach.
(Inherited from IStructure.) | |
Type |
Structure type, unique for each type of structure.
(Inherited from IStructure.) | |
UpstreamWaterLevel |
Upstream water level. Upstream refers to the direction of chainage. The water level is set by use of
SetWaterLevels
Unit: [m]
(Inherited from IStructure.) | |
WaterLevelDatum |
Datum to be applied to all water levels specified in the table.
Type: water level
Unit: [meter]
Default: 0.0
|