Public propertyActualGateLevel
Actual gate level. Type: River Structure Geometry Unit: [m] Default: 0

this is not a setup parameter, but a run parameter, which will change during the run (if the gate is controlled). If the gate is not controlled, this can be used to change the gate (manual/user defined control).

(Inherited from IGate.)
Public propertydDischargedDownStreamWaterLevel
Calculated Discharge derivative with UpStreamWaterLevel. Upstream is relative to the direction of chainage. Unit: [m^2/s]
(Inherited from IStructure.)
Public propertydDischargedUpStreamWaterLevel
Calculated Discharge derivative with DownStreamWaterLevel. Downstream is relative to the direction of chainage. Unit: [m^2/s]
(Inherited from IStructure.)
Public propertyDelhs
Level from where the variation is forced to be linear.
(Inherited from ILinearZeroVariation.)
Public propertyDischarge
Calculated Discharge Unit: [m^3/s]
(Inherited from IStructure.)
Public propertyDownstreamWaterLevel
Downstream water level.Downstream refers to the direction of chainge. The water level is set by use of SetWaterLevels Unit: [m]
(Inherited from IStructure.)
Public propertyFlowFactor
The discharge (and discharge derivatives) are scaled by the flow factor.
(Inherited from IStructure.)
Public propertyHeight
Height above sill of the overflow crest of the gate when the gate is closed. Type: River Structure Geometry Unit: [m] Default: 1
Public propertyHorizontalOffSetFromMarker2
Horizontal offset of the structures compared to its limiting cross sections.
(Inherited from IPlotableStructure.)
Public propertyID
Name of the structure.
(Inherited from IStructure.)
Public propertyIDInUserUnit Obsolete.
Used to get a consistent description of the structure. The ID comes in user units. Used e.g. when reporting errors, warnings and hints.
(Inherited from IStructure.)
Public propertyImplicit
Flag to control if the structure is implicit or explicit. If the structure is explicit (Implicit == false) then the derivatives of the discharge are always zero. Default value: true
(Inherited from IStructure.)
Public propertyInitialGateLevel
Gate level. Type: River Structure Geometry Unit: [m] Default: 0
(Inherited from IGate.)
Public propertyInvertLevelDownstream
Invert level down stream The invert level is the level where water starts flowing in to the structure from the downstream side. It does not necessarily flow through the structure.
(Inherited from IStructure.)
Public propertyInvertLevelUpstream
Invert level up stream. The invert level is the level where water starts flowing in to the structure from the upstream side. It does not necessarily flow through the structure.
(Inherited from IStructure.)
Public propertyLength Obsolete.
Length of the structure. Unit: [m]
(Inherited from IStructure.)
Public propertyLocation
Location of structure.
(Inherited from IStructure.)
Public propertyMaxSpeed
The maximum allowed rate of change of the gate level. Type: River Structure Geometry / Time Unit: [m] Default: 0.001
(Inherited from IGate.)
Public propertyMaxValue
Maximum gate level. The gate can not be raised above this level. Type: River Structure Geometry Unit: [m] Default: 0
(Inherited from IGate.)
Public propertyMultiplicator
Multiplicator or "number of structures" of this type. Used for modelling more structures at the same location with the same geometry in one go. Unit: [] Default: 1
(Inherited from IGate.)
Public propertyRadius
Radius of gate. Type: River Structure Geometry Unit: [m] Default: 1
Public propertyRunTimeDiagnostics
The getter is used to get a list of errors. OBSOLETE
(Inherited from IStructure.)
Public propertySideStructureBank
Bank side that side-structure is located on

If side structure contains reservoir, and has the Coordinate set, this is not used (and should be set to Undefined).

(Inherited from IStructure.)
Public propertySideStructureReservoir
Reservoir at end of side structure. Null if not side structure, or no reservoir is defined
(Inherited from IStructure.)
Public propertySillLevel
Level of the sill of the gate. Type: River Structure Geometry Unit: [m] Default: 0
(Inherited from IGate.)
Public propertyStructureType
Type of structure
(Inherited from IStructure.)
Public propertyTopoID
TopoID used when structure is searching for neighboring cross sections in the reach.
(Inherited from IStructure.)
Public propertyTransitionBottom
Parameter used to define the transition zone between free flow and submerged flow. Type: River Structure Geometry Unit: [m] Default: -0.152
Public propertyTransitionDepth
Parameter used to define the transition zone between free flow and submerged flow. Type: River Structure Geometry Unit: [m] Default: 0.304
Public propertyTrunnion
Height above sill of centre of gate circle. Type: River Structure Geometry Unit: [m] Default: 1
Public propertyTuneFactor
Discharge calibration factor. This factor is used only on the part of the discharge that flows below the gate. Type: Dimensional factor Unit: [] Default: 1
Public propertyType
Structure type, unique for each type of structure.
(Inherited from IStructure.)
Public propertyUpstreamWaterLevel
Upstream water level. Upstream refers to the direction of chainage. The water level is set by use of SetWaterLevels Unit: [m]
(Inherited from IStructure.)
Public propertyUseMaxValue
Flag telling if the maximum gate level specified in _maxValue should be used Type: boolean Unit: [m] Default: false
(Inherited from IGate.)
Public propertyWeirCoefficient
Coefficient used when calculating the flow above the gate. Type: Dimensional factor Unit: [] Default: 1.838
Public propertyWeirExponent
Coefficient used when calculating the flow above the gate Type: Dimensional factor Unit: [] Default: 1.5
Public propertyWidth
Width of the weir opening. Width is perpendicular to the flow direction, i.e. "across the river"