IPump Properties |
The IPump type exposes the following members.
Name | Description | |
---|---|---|
AccelerationTime |
Acceleration time
| |
ConstantFlow |
Set the constant flow rate
| |
dDischargedDownStreamWaterLevel |
Calculated Discharge derivative with UpStreamWaterLevel. Upstream is relative to the direction of chainage.
Unit: [m^2/s]
(Inherited from IStructure.) | |
dDischargedUpStreamWaterLevel |
Calculated Discharge derivative with DownStreamWaterLevel. Downstream is relative to the direction of chainage.
Unit: [m^2/s]
(Inherited from IStructure.) | |
DecelerationTime |
Deceleration time
| |
Discharge |
Calculated Discharge
Unit: [m^3/s]
(Inherited from IStructure.) | |
DischargeControlActive |
Must be set to true to activate (external) control of discharge (through a PID control or similar).
If pump is controlled through ControlMoudle, this will set this automatically (during Prepare) Can not be combined with StartStopLevelControlActive | |
DownstreamWaterLevel |
Downstream water level.Downstream refers to the direction of chainge. The water level is set by use of
SetWaterLevels
Unit: [m]
(Inherited from IStructure.) | |
FlowFactor |
The discharge (and discharge derivatives) are scaled by the flow factor.
(Inherited from IStructure.) | |
HQRelation |
QH relation for QdeltaH and QH pumps,
(dH, Q) or (H, Q) pairs. The XYTable ensures that dH (or H) is always increasing.
For QdeltaH, a positive dH is the height that water must be RAISED across the pump. When DischargeControlActive is set (e.g. PID controlled pump) this HQ relation is the maximum pump capacity. Set to null if no maximum capacity. | |
HQRelationMinimumCapacity |
QH relation for QH and QdeltaH pumps
Minimum discharge allowed for a discharge controlled pump (e.g. PID).
Set to null to disable.
| |
ID |
Name of the structure.
(Inherited from IStructure.) | |
IDInUserUnit | Obsolete.
Used to get a consistent description of the structure. The ID comes in user units. Used e.g. when
reporting errors, warnings and hints.
(Inherited from IStructure.) | |
Implicit |
Flag to control if the structure is implicit or explicit. If the structure is explicit
(Implicit == false) then the derivatives of the discharge are always zero.
Default value: true
(Inherited from IStructure.) | |
InvertLevelDownstream |
Invert level down stream
The invert level is the level where water starts
flowing in to the structure from the downstream side.
It does not necessarily flow through the structure.
(Inherited from IStructure.) | |
InvertLevelUpstream |
Invert level up stream.
The invert level is the level where water starts
flowing in to the structure from the upstream side.
It does not necessarily flow through the structure.
(Inherited from IStructure.) | |
IsSideStructure | Obsolete.
A side structure is connected to a reservoir downstream (chainage direction).
| |
IsVariableSpeed |
True if the pump supports variable speed operation (must be true for PID controlled pumps).
Default value: false
| |
Length | Obsolete.
Length of the structure.
Unit: [m]
(Inherited from IStructure.) | |
Location |
Location of structure.
(Inherited from IStructure.) | |
MaxStartLevel |
Maximum stop level used if an external control is active. If an external control is active, then MinStopLevel
and MaxStopLevel must be set.
| |
MinStopLevel |
Minimum stop level used if an external control is active. If an external control is active, then MinStopLevel
and MaxStopLevel must be set.
| |
MinTimeOff |
Minimum time the pump should stay off if it stops pumping.
This is only applicable when StartStopLevelControlActive.
Default value is 0 seconds.
| |
MinTimeOn |
Minimum time the pump should stay on if it starts pumping.
This is only applicable when StartStopLevelControlActive.
Default value is 0 seconds.
| |
Offset |
Offset on water level
| |
OffsetMinDischarge |
Offset to use when looking up the minimum discharge for the pump. Only used when a PID control is
attached to the pump.
| |
OutletLevel |
Set the level of the outlet/reservoir
For side structures (StructureType == SideStructure) and flow direction is upstream (negative Q), then the downstream level is equal to this reservoir level. If Q is positive, then OutletLevel is used as the downstream end. Default value is MinValue, effectively disabling the use of the OutletLevel | |
PumpType |
Type of pump
| |
ReservoirLevel | Obsolete.
Same as OutletLevel | |
RunTimeDiagnostics |
The getter is used to get a list of errors. OBSOLETE
(Inherited from IStructure.) | |
SideStructureBank |
Bank side that side-structure is located on
(Inherited from IStructure.)If side structure contains reservoir, and has the Coordinate set, this is not used (and should be set to Undefined). | |
SideStructureReservoir |
Reservoir at end of side structure. Null if not side structure, or no reservoir is defined
(Inherited from IStructure.) | |
StartLevel |
The water level at which the pump is activated
| |
StartStopLevelControlActive |
Must be set to true to activate external control of start and stop levels (through a PID control or similar).
If pump is controlled through ControlModule, this will set this automatically (during Prepare) Can not be combined with DischargeControlActive | |
StopLevel |
The water level at which the pump is de-activated
| |
StructureType |
Type of structure
(Inherited from IStructure.) | |
TopoID |
TopoID used when structure is searching for neighboring cross sections in the reach.
(Inherited from IStructure.) | |
Type |
Structure type, unique for each type of structure.
(Inherited from IStructure.) | |
UpstreamWaterLevel |
Upstream water level. Upstream refers to the direction of chainage. The water level is set by use of
SetWaterLevels
Unit: [m]
(Inherited from IStructure.) | |
UseMaximumDischarge |
If true, then the maximum alloved discharge is taken from the MaxPumpDischargeUpstream and
MaxPumpDischargeUpstream are use to directly set the maximum discharge.
Default false.
| |
UseSuppressionFactor |
If true, then suppresion factors from the PumpSuppressionFactorUpstream and
PumpSuppressionFactorDownstream delegates are used to limit the available discharge of the pump.
Default false.
|