SolverSettingsUseOscillationDamping Property |
Oscillations is often seen when the solution change is shifting sign from one time step ([n-1]->[n]) to the next time step ([n]->[n+1]), i.e. first decreasing and then increasing. The oscillation damping procedure will look for shifting in sign-change, but only apply actual damping when the two conditions in OscillationHChangeLimit or OscillationQChangeLimit is met.
Default is false.
Namespace: DHI.Mike1D.HDParameterDataAccess