YarnellBridge Fields | 
The YarnellBridge type exposes the following members.
| Name | Description | |
|---|---|---|
| _accepts | 
            List of quantities that are accepted
              (Inherited from Structure.) | |
| _columnHeader | (Inherited from BridgeTabulated.) | |
| _controlStategyId | 
            If the structure is being controlled, then _controlStategyId contains the ID of the
            active control strategy
              (Inherited from Structure.) | |
| _downstreamWaterLevel | 
            Downstream water level, as set by SetWaterLevels(Double, Double)
            Unit: [m]
              (Inherited from Structure.) | |
| _dqdhDownstream | 
            The derivative of flow through the structure with downstream water level. The flow is 
            calculated in the derived classes when the SetWaterLevels method is called.
            Unit: [m2/sec]
              (Inherited from Structure.) | |
| _dqdhUpstream | 
            The derivative of flow through the structure with upstream water level. The flow is 
            calculated in the derived classes when the SetWaterLevels method is called.
            Unit: [m2/sec]
              (Inherited from Structure.) | |
| _flowArea | 
            Flow area through structure. Used by most (but not all) structures.
              (Inherited from Structure.) | |
| _flowDir | 
            FlowDir is used to determine which parameters to use for the flow calculations. 
            Derived by the SetWaterLevels(Double, Double).
              (Inherited from Structure.) | |
| _gridSizeDownStream | (Inherited from BridgeBase.) | |
| _gridSizeUpStream | (Inherited from BridgeBase.) | |
| _id | 
            Identification name of the structure
              (Inherited from Structure.) | |
| _implicit | 
            If _implicit == false, then the derivatives are always zero.
            Default value: true.
              (Inherited from Structure.) | |
| _location | 
            Location in the network
              (Inherited from Structure.) | |
| _offers | 
            List of quantities that are offered
              (Inherited from Structure.) | |
| _q | 
            Flow through the structure. The flow is calculated in the derived classes when the 
            SetWaterLevels method is called.
            Unit: [m3/sec]
              (Inherited from Structure.) | |
| _rowHeader | (Inherited from BridgeTabulated.) | |
| _runTimeDiagnostics | 
            Diagnostics are written into this Diagnostics during calculations.
            Set during Initialize(IDiagnostics)  (Inherited from Structure.) | |
| _table | (Inherited from BridgeTabulated.) | |
| _topoID | 
            Identification used to find referenced cross sections
              (Inherited from Structure.) | |
| _upstreamWaterLevel | 
            Upstream water level, as set by SetWaterLevels(Double, Double)
            Unit: [m]
              (Inherited from Structure.) | |
| _waterLevelDatum | (Inherited from BridgeTabulated.) |