StructureLinearisation Method

Makes linearisation for heads smaller than delH. Note that it is assumed that the flow is positive so this should be called before taking flow direction into account.

Definition

Namespace: DHI.Mike1D.StructureModule
Assembly: DHI.Mike1D.StructureModule (in DHI.Mike1D.StructureModule.dll) Version: 24.0.0.0 (11.1.1.1111)
C#
protected static void Linearisation(
	ref double flow,
	ref double dQdHups,
	ref double dQdHdws,
	double delH,
	double head
)

Parameters

flow  Double
Calculated POSITIVE flow for a head equal to delH
dQdHups  Double
Derivative of flow with respect to upstream water level
dQdHdws  Double
Derivative of flow with respect to downstream water level
delH  Double
Heads below or equal to delH is linearised
head  Double
Actual head across the structure

See Also