| _accepts |
List of quantities that are accepted
(Inherited from Structure) |
| _actualGateLevel | Gate level. Type: River Structure Geometry Unit: [m] Default: 0 |
| _controlStategyId |
If the structure is being controlled, then _controlStategyId contains the ID of the
active control strategy
(Inherited from Structure) |
| _downstreamWaterLevel |
Downstream water level, as set by SetWaterLevels(Double, Double)
Unit: [m]
(Inherited from Structure) |
| _dqdhDownstream |
The derivative of flow through the structure with downstream water level. The flow is
calculated in the derived classes when the SetWaterLevels method is called.
Unit: [m2/sec]
(Inherited from Structure) |
| _dqdhUpstream |
The derivative of flow through the structure with upstream water level. The flow is
calculated in the derived classes when the SetWaterLevels method is called.
Unit: [m2/sec]
(Inherited from Structure) |
| _dynamicMaxGateLevel | Controllable minimum gate level |
| _dynamicMinGateLevel | Controllable maximum gate level |
| _flowArea |
Flow area through structure. Used by most (but not all) structures.
(Inherited from Structure) |
| _flowDir |
FlowDir is used to determine which parameters to use for the flow calculations.
Derived by the SetWaterLevels(Double, Double).
(Inherited from Structure) |
| _id |
Identification name of the structure
(Inherited from Structure) |
| _implicit |
If _implicit == false, then the derivatives are always zero.
Default value: true.
(Inherited from Structure) |
| _initialGateLevel | Initial value of the gate level. Type: River Structure Geometry Unit: [m] Default: 0 |
| _location |
Location in the network
(Inherited from Structure) |
| _maxSpeed | The maximum allowed rate of change of the gate level. Type: River Structure Geometry / Time Unit: [m] Default: 0.001 |
| _maxValue | Maximum gate level. The gate can not be raised above this level. Type: River Structure Geometry Unit: [m] Default: 0 |
| _multiplicator | Multiplicator or "number of structures" of this type. Used for modelling more structures at the same location with the same geometry in one go. Unit: [] Default: 1 |
| _offers |
List of quantities that are offered
(Inherited from Structure) |
| _previousGateLevel | Previous gate level. Used when control is active, to assure the correct speed of the gate. |
| _q |
Flow through the structure. The flow is calculated in the derived classes when the
SetWaterLevels method is called.
Unit: [m3/sec]
(Inherited from Structure) |
| _runTimeDiagnostics |
Diagnostics are written into this Diagnostics during calculations.
Set during Initialize(IDiagnostics) (Inherited from Structure) |
| _sillLevel | Level of the sill of the gate. |
| _timeOfPreviousGateLevelChange | Time of previous gate level change |
| _topoID |
Identification used to find referenced cross sections
(Inherited from Structure) |
| _upstreamWaterLevel |
Upstream water level, as set by SetWaterLevels(Double, Double)
Unit: [m]
(Inherited from Structure) |
| _useDynamicMaxGateLevel | Use the controllable maximum gate level |
| _useDynamicMinGateLevel | Use the controllable minimum gate level |
| _useMaxValue | Flag telling if the maximum gate level specified in _maxValue should be used Type: boolean Unit: [m] Default: false |
| _width | Width of the weir opening. Width is perpendicular to the flow direction, i.e. "across the river" |