Gate Fields

Fields

_accepts List of quantities that are accepted
(Inherited from Structure)
_actualGateLevel Gate level. Type: River Structure Geometry Unit: [m] Default: 0
_controlStategyId If the structure is being controlled, then _controlStategyId contains the ID of the active control strategy
(Inherited from Structure)
_downstreamWaterLevel Downstream water level, as set by SetWaterLevels(Double, Double) Unit: [m]
(Inherited from Structure)
_dqdhDownstream The derivative of flow through the structure with downstream water level. The flow is calculated in the derived classes when the SetWaterLevels method is called. Unit: [m2/sec]
(Inherited from Structure)
_dqdhUpstream The derivative of flow through the structure with upstream water level. The flow is calculated in the derived classes when the SetWaterLevels method is called. Unit: [m2/sec]
(Inherited from Structure)
_dynamicMaxGateLevel Controllable minimum gate level
_dynamicMinGateLevel Controllable maximum gate level
_flowArea Flow area through structure. Used by most (but not all) structures.
(Inherited from Structure)
_flowDir FlowDir is used to determine which parameters to use for the flow calculations. Derived by the SetWaterLevels(Double, Double).
(Inherited from Structure)
_id Identification name of the structure
(Inherited from Structure)
_implicit If _implicit == false, then the derivatives are always zero. Default value: true.
(Inherited from Structure)
_initialGateLevel Initial value of the gate level. Type: River Structure Geometry Unit: [m] Default: 0
_location Location in the network
(Inherited from Structure)
_maxSpeed The maximum allowed rate of change of the gate level. Type: River Structure Geometry / Time Unit: [m] Default: 0.001
_maxValue Maximum gate level. The gate can not be raised above this level. Type: River Structure Geometry Unit: [m] Default: 0
_multiplicator Multiplicator or "number of structures" of this type. Used for modelling more structures at the same location with the same geometry in one go. Unit: [] Default: 1
_offers List of quantities that are offered
(Inherited from Structure)
_previousGateLevel Previous gate level. Used when control is active, to assure the correct speed of the gate.
_q Flow through the structure. The flow is calculated in the derived classes when the SetWaterLevels method is called. Unit: [m3/sec]
(Inherited from Structure)
_runTimeDiagnostics Diagnostics are written into this Diagnostics during calculations. Set during Initialize(IDiagnostics)
(Inherited from Structure)
_sillLevel Level of the sill of the gate.
_timeOfPreviousGateLevelChange Time of previous gate level change
_topoID Identification used to find referenced cross sections
(Inherited from Structure)
_upstreamWaterLevel Upstream water level, as set by SetWaterLevels(Double, Double) Unit: [m]
(Inherited from Structure)
_useDynamicMaxGateLevel Use the controllable maximum gate level
_useDynamicMinGateLevel Use the controllable minimum gate level
_useMaxValue Flag telling if the maximum gate level specified in _maxValue should be used Type: boolean Unit: [m] Default: false
_width Width of the weir opening. Width is perpendicular to the flow direction, i.e. "across the river"

See Also